Oscillation
11.1 Asynchronous oscillation (OS, OSP1, OSP2, OST1, OST2, OSCTRL, OSNSC, OSE, OSB)
Oscillation reversal points
The current offsets must be taken into account when oscillation positions are defined:
Absolute specification
OSP1[Z]=<value>
Position of reversal point = sum of offsets + programmed value
Relative specification
OSP1[Z]=IC(<value>)
Position of reversal point = reversal point 1 + programmed value
Example:
Program code
N10 OSP1[Z]=100 OSP2[Z]=110
...
...
N40 OSP1[Z]=IC(3)
WAITP
If oscillation is to be performed with a geometry axis, this axis must be enabled for oscillation
with WAITP.
When oscillation has finished, WAITP is used to enter the oscillating axis as a positioning axis
again, so that normal use can resume.
Oscillation with motion-synchronous actions and stopping times
Once the set stop times have expired, the internal block change is executed during oscillation
(indicated by the new distances to go of the axes). The deactivation function is checked when
the block changes. The deactivation function is defined according to the control setting for the
motion sequence (OSCTRL).
An oscillation stroke may then be executed before the sparking-out strokes are started or the
end position approached.
this is not in fact the case.
656
This dynamic response can be influenced by the feed override.
Although it appears as if the deactivation response has changed,
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0