Siemens Sinumerik 840D sl Programming Manual page 150

Job planning
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Flexible NC programming
1.20 Read lines in the file (READ)
<file name>:
<start line>:
<number of
lines>:
150
Name of the file to be read (call-by-value parameter)
Type:
STRING
The following points should be noted when specifying the file name:
The specified file name must not contain any blank spaces or
control characters (characters with ASCII code ≤ 32), otherwise
the READ command will be canceled with error code 1 "Path not
allowed".
The file name can be specified with path data and file identifier.
– Path data
Path data must be absolute, i.e. start with "/".
If a path is not specified, the file is searched for in the current
directory (= directory of selected program).
– File identifier
If the file name does not contain a domain identifier ("_N_"), it
is added accordingly.
If the fourth-last character of the file name is an underscore
"_", the next three characters will be interpreted as the file
identifier. In order to be able to use the same file name for all
file commands, e.g. via a STRING type variable, only the
_SPF and _MPF file identifiers may be used.
If there is no "_MPF" or "_SPF" identifier, the file name is
automatically completed with _MPF.
The file name length can be up to 32 bytes, the path length up to
128 bytes.
Example:
"PROTFILE"
"_N_PROTFILE"
"_N_PROTFILE_MPF"
"/_N_MPF_DIR_/_N_PROTFILE_MPF/"
Start line of the section of the file to be read (call-by-value parameter)
Type:
INT
Value:
0
Reads the number of lines specified with the
<number of lines> parameter before the
end of the file.
1 to n
Number of the first line to be read.
Number of lines to be read (call-by-value parameter)
Type:
INT
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0
Job planning

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de slSinumerik 828d

Table of Contents