Special Motion Commands
4.7 Measurements with touch trigger probe (MEAS, MEAW)
Reading measurement results
The measurement results for the axes acquired with probes are available in the following
variables:
• $AA_MM[<axis>]
Measurement results in the machine coordinate system
• $AA_MW[<axis>]
Measurement results in the workpiece coordinate system
No internal preprocessing stop is generated when these variables are read.
Note
A preprocessing stop must be programmed with STOPRE at the appropriate position in the
program. The system will otherwise read false values.
Syntax
MEAS=<TE> G... X... Y... Z...
MEAW=<TE> G... X... Y... Z...
Significance
MEAS
MEAW
<TE>
G...
X... Y... Z... End point in Cartesian coordinates
272
Command: Measuring with deletion of distance-to-go
Effective:
non-modal
Command: Measuring without deletion of distance-to-go
Effective:
non-modal
Trigger event to initiate measurement
Type:
INT
Range of values:
-2, -1, 1, 2
Note:
There are up to a maximum of 2 probes
(dependent on configuration level).
Significance:
(+)1
Rising edge of probe 1 (measuring input 1)
-1
Falling edge of probe 1 (measuring input 1)
(+)2
Rising edge of probe 2 (measuring input 2)
-2
Falling edge of probe 2 (measuring input 2)
Note:
There are up to a maximum of 2 probes (dependent on configuration
level).
Type of interpolation, e.g. G0, G1, G2 or G3
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0