Connectors and binectors
Binector
Name, description
B0054
Overrflow of actual position value
This binector changes to 1 when connector KK0046 (actual position value extended in software to a 32-bit
value) counts from value 7FFF FFFFH (= +2
Binector B0054 does not change back to 0 until connector KK0046 assumes a value other than 8000 0000H
31
(= –2
) again.
Evaluation of the pulse encoder board SBP
Position acquisition of SBP, underflow
B0055
Position acquisition of SBP, overflow
B0056
Monitoring of the armature currents
1 = Commutation failure or overcurrent has occurred
B0057
Status word 1
B0100
Stat.word 1, bit 0:
Stat.word 1, bit 0 inverted
B0101
B0102
Stat.word 1, bit 1:
B0103
Stat.word 1, bit 1 inverted
Stat.word 1, bit 2:
B0104
Stat.word 1, bit 2 inverted
B0105
B0106
Stat.word 1, bit 3:
Stat.word 1, bit 3 inverted
B0107
Stat.word 1, bit 4:
B0108
B0109
Stat.word 1, bit 4 inverted
B0110
Stat.word 1, bit 5:
Stat.word 1, bit 5 inverted
B0111
B0112
Stat.word 1, bit 6:
B0113
Stat.word 1, bit 6 inverted
Stat.word 1, bit 7:
B0114
B0115
Stat.word 1, bit 7 inverted
B0116
Stat.word 1, bit 8:
Stat.word 1, bit 8 inverted
B0117
Stat.word 1, bit 10: 0=comparison setpoint not reached, 1=comparison setpoint reached
B0120
B0121
Stat.word 1, bit 10 inverted
Stat.word 1, bit 11: 0=undervoltage fault not active, 1=undervoltage fault active
B0122
Stat.word 1, bit11 inverted
B0123
B0124
Stat.word 1, bit 12: 0=main contactor request not active, 1=request to energize main contactor active
B0125
Stat.word 1, bit 12 inverted
Stat.word 1, bit 13: 0=ramp-function generator not active, 1=ramp-function generator active
B0126
B0127
Stat.word 1, bit 13 inverted
B0128
Stat.word 1, bit 14: 0=negative speed setpoint, 1=positive speed setpoint
Stat.word 1, bit 14 inverted
B0129
Status word 2
Stat.word 2, bit 18: 0=overspeed, 1=no overspeed
B0136
Stat.word 2, bit 18 inverted
B0137
B0138
Stat.word 2, bit 19: 0=no external fault 1 active, 1=external fault 1 active
B0139
Stat.word 2, bit 19 inverted
Stat.word 2, bit 20: 0=no external fault 2 active, 1=external fault 2 active
B0140
B0141
Stat.word 2, bit 20 inverted
B0142
Stat.word 2, bit 21: 0=no external alarm active, 1=external alarm active
12-28
31
–1) to value 8000 0000H (= –2
0=not ready to switch on, 1=ready to switch on
0=not ready, 1=ready (pulses disabled)
0=pulses disabled, 1=Run (output terminals energized)
0=no active fault, 1=active fault (pulses disabled)
0=OFF2 active, 1=no active OFF2
0=OFF3 active, 1=no active OFF3
0=no starting lockout (unit can be switched on), 1=starting lockout active
0=no active alarm, 1=alarm active
0=setp./act. val. deviation detected, 1=no setp./act. val. deviation
[SW 1.9 and later]
31
).
[SW 2.0 and later]
[SW 2.0 and later]
[SW 2.0 and later]
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
Function
diag., Sheet
G145
Z120
Z120
G162
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G182
G183
G183
G183
G183
G183
G183
G183