Siemens 6RA7086-6KS22 Operating Instructions Manual page 361

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
Example 2:
The following settings need to be made to create the correct links:
P044.index01 = 401: Links connector K0401 to the 1
P044.index02 = 402: Links connector K0402 to the 2
The following values are now displayed in parameter r043:
Setting parameters
(see also Section "Data sets")
In addition to the parameters that are used to select a signal (connector, binector), there are also
parameters which define an operating mode or the parameter value of some function.
Representation in function diagrams:
Apart from parameter numbers, the function diagrams may also contain the factory setting, function
and value range of parameters as supplementary information.
P109 (0)
P462.F(10.00s)
(0.01...300.00s)
Ramp-up time
Examples:
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
The contents of connectors K0401 and K0402 must be output on the connector displays
(parameter r043)
Section 8, Sheet G121:
r043.01
r043.03
r043.02
P044 (0)
.01
401
K
.02
402
K
.03
K
.04
K
.05
K
.06
K
.07
K
r043.index01: Contents of connector K0401
r043.index02: Contents of connector K0402
r043.index03
to
r043.index07: Parameter P044.index.03 to 07 remain at the works setting (0) (value in
brackets next to parameter number) in this example, i. e. the contents
of connector K0000 (=fixed value 0) are displayed on r043.index.03 to
.07.
Setting parameter
Parameter number = P109, factory setting = 0
Setting parameter in function parameter set (".F" after parameter number)
Parameter number = P462, factory setting = 10.00s
Value range = 0.01...300.00s
Parameter for setting ramp-up time
P700 in Section 8, Sheet G113 defines the signal type of the analog input
(voltage input ±10V, current input 0...20mA, current input 4...20mA).
P705 in Section 8, Sheet G113 defines the filter time for the analog input (adjustable
in ms).
Parameters P520 to P530 in Section 8, Sheet G153 determine the shape of the friction
characteristic.
P465 in Section 8, Sheet G126 determines whether the time settings must be multiplied
by a factor of 1 or 60.
st
connector display
nd
connector display
r043.05
r043.07
r043.04
r043.06
Function descriptions
9-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents