Parameter list
PNU
Description
Technology controller: Controller parameters
U488
P gain
(2488)
S00
FDS
(B170)
U489
Source for input quantity (x) for Kp adaptation
(2489)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B170)
U490
Characteristic for Kp adaptation: Threshold 1 (x1)
(2490)
S00
FDS
(B170)
U491
Characteristic for Kp adaptation: Threshold 2 (x2)
(2491)
S00
FDS
(B170)
U492
Characteristic for Kp adaptation: Minimum value (y1)
(2492)
Minimum value of Kp factor (y) when x ≤ x1
S00
FDS
(B170)
U493
Characteristic for Kp adaptation: Maximum value (y2)
(2493)
Maximum value of Kp factor (y) when x ≥ x2
S00
FDS
(B170)
U494
Reset time
(2494)
See also U495
S00
FDS
(B170)
U495
Factor for reset time
(2495)
0
Reset time = U494 * 1
*
1
Reset time = U494 * 1000
S00
FDS
(B170)
Technology controller: Speed droop
A parameterizable feedback loop can be connected in parallel to the I and P components of the technology controller (acts on summation
point of setpoint and actual value). This loop can be activated and deactivated by settings in parameter U496 (loop can also be
deactivated by setting U497 = 0).
U496
Source for control bit for speed droop injection
(2496)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B170)
U497
Speed droop
(2497)
Example:
S00
A 10% speed droop setting causes a 10% reduction in the setpoint at a
FDS
100% controller output ("softening" of closed-loop control).
(B170)
U498
Positive limit for speed droop
(2498)
S00
FDS
(B170)
U499
Negative limit for speed droop
(2499)
S00
FDS
(B170)
11-142
Value range
[Unit]
Steps
FB 114 0.10 to 200.00
0.01
All connector
FB 114
numbers
1
FB 114 0.00 to 200.00
[%]
0.01
FB 114 0.00 to 200.00
[%]
0.01
0.10 to 30.00
FB 114
0.01
0.10 to 30.00
FB 114
0.01
0.010 to 60.000
FB 114
[s]
0.001
0 to 1
FB 114
1
All binector numbers
FB 114
1
0.0 to 60.0
FB 114
[%]
0.1
FB 114 0.00 to 199.99
[%]
0.01
FB 114 -200.00 to 0.00
[%]
0.01
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=3.00
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=100.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=1.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=1.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=3.000
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
FS=0.0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=100.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=-100.00
P051 = 40
Type: I2
Online