Siemens 6RA7086-6KS22 Operating Instructions Manual page 561

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
r958
Alarm parameter 6
Parameter alarms 6 (CB alarms)
If one of the alarms between 81 and 96 is generated, the corresponding
segment in the display lights up.
r959
Alarm parameter 7
Parameter alarms 7 (TB alarms 1)
If one of the alarms between 97 and 112 is generated, the corresponding
segment in the display lights up.
r960
Alarm parameter 8
Parameter alarms 8 (TB alarms 2)
If one of the alarms between 113 and 128 is generated, the corresponding
segment in the display lights up.
11.49 Device identification
r964
Parameters for device identification on the PROFIBUS
Display parameters to support overview and diagnosis of all nodes on the
PROFIBUS-DP during and after commissioning
(coding according to PROFIBUS profile V3)
i001:
Display of the manufacturer of the
SIMOREG DC Master 6RA70 : SIEMENS = 42
i002:
Display of device type: SIMOREG DC Master 6RA70 = 4110
i003:
Display of the software version of the SIMOREG DC Master
6RA70
(see r060.001)
i004:
Display of year of generation of the software of the SIMOREG
DC Master 6RA70: y y y y
(see r061.001)
i005:
Display of the month and day of generation of the software of
the SIMOREG DC Master 6RA70: d d m m
(see r061.003 and r061.002)
i006:
Display of the controlled axes of the SIMOREG DC Master
6RA70: 1
11.50 Visualization parameters: Control and status word
r967
Display of control word 1
Visualization parameter for control word 1 (bits 0-15)
Identical to r650 (control word 1)
r968
Display of status word 1
Visualization parameter for status word 1 (bits 0 - 15)
Identical to r652 (status word 1)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
96
95
94
93
92
91
90
88
87
86
85
84
83
82
112
111
110
109
108
107
106
104
103
102
101
100 99
98
128
127
126
125
124
123
122
120
119
118
117
116 115 114 113
Value range
[Unit]
Steps
89
81
105
97
121
0 to 65535
[SW 2.0 and later]
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
Ind: 6
P052 = 1
Type: O2
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
11-97