Siemens 6RA7086-6KS22 Operating Instructions Manual page 586

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
U262
Source for control signals
(2262)
i001
Source for "Stop integrator" signal
*
(integrator is stopped when binector reaches log. "1" state)
S00
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
(B155)
value entered in parameter U263)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U263
Source for setting value
(2263)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B155)
Integrator 2 (output = K9221)
U264
Source for input quantity
(2264)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B155)
U265
Integral-action time
(2265)
S00
(B155)
U266
Source for control signals
(2266)
i001
Source for "Stop integrator" signal
*
(integrator is stopped when binector reaches log. "1" state)
S00
i002
Source for "Set integrator" signal
(when binector reaches log. "1" state, the integrator is set to the
(B155)
value entered in parameter U267)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U267
Source for setting value
(2267)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B155)
Integrator 3 (output = K9222)
U268
Source for input quantity
(2268)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B155)
U269
Integral-action time
(2269)
S00
(B155)
U270
Source for control signals
(2270)
i001
Source for "Stop integrator" signal
*
(integrator is stopped when binector reaches log. "1" state)
S00
i002
Source for "Set integrator" signal
(B155)
(when binector reaches log. "1" state, the integrator is set to the
value entered in parameter U271)
Settings:
0 = binector B0000
1 = binector B0001
etc.
11-122
Value range
[Unit]
Steps
All binector numbers
FB 100
1
All connector
FB 100
numbers
1
All connector
FB 101
numbers
1
FB 101 10 to 65000
[ms]
1
All binector numbers
FB 101
1
All connector
FB 101
numbers
1
All connector
FB 102
numbers
1
FB 102 10 to 65000
[ms]
1
All binector numbers
FB 102
1
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=10
P051 = 40
Type: O2
Online
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=10
P051 = 40
Type: O2
Online
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents