Siemens 6RA7086-6KS22 Operating Instructions Manual page 572

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
th
U126
Operands for 7
(2126)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
th
U127
Operands for 8
(2127)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
th
U128
Operands for 9
(2128)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
U129
Operands for 10
(2129)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
U130
Operands for 11
(2130)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
U131
Operands for 12
(2131)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
Adders / subtracters for double word connectors
The 3 operands of a function block are selected in each case via the three indices of a parameter.
The result is switched to a double word connector and a connector.
The double word connector is limited to between -200.00 and +199.99%.
The connector is limited to between –0.003052 and +0.003052% (= value range of LOW word of a double word connector
= ± 200% / 65536)
st
U132
Operands for 1
(2132)
nd
Operands for 2
*
st
S00
1
adder / subtracter: result = KK9490 and K9491
nd
2
adder / subtracter: result = KK9492 and K9493
(B151)
i001:
Addition value for 1
i002:
Addition value for 1
i003:
Subtraction value for 1
i004:
Addition value for 2
i005:
Addition value for 2
i006:
Subtraction value for 2
Settings:
0 = connector K0000
1 = connector K0001
etc.
Sign inverters
The contents of the connector selected in the parameter are negated (two's complement). The result is applied to the specified connector.
st
sign inverter (result = K9135)
U135
Source for 1
(2135)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
nd
sign inverter (result = K9136)
U136
Source for 2
(2136)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
rd
sign inverter (result = K9137)
U137
Source for 3
(2137)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
11-108
adder / subtracter (result = K9126)
adder / subtracter (result = K9127)
adder / subtracter (result = K9128)
th
adder / subtracter (result = K9129)
th
adder / subtracter (result = K9130)
th
adder / subtracter (result = K9131)
adder / subtracter
adder / subtracter
st
adder/subtracter
st
adder/subtracter
st
adder/subtracter
nd
adder/subtracter
nd
adder/subtracter
nd
adder/subtracter
Value range
[Unit]
Steps
All connector
FB 26
numbers
1
All connector
FB 27
numbers
1
All connector
FB 28
numbers
1
All connector
FB 29
numbers
1
All connector
FB 30
numbers
1
All connector
FB 31
numbers
1
All connector
FB 48
numbers
FB 49
1
[SW 1.9 and later]
All connector
FB 35
numbers
1
All connector
FB 36
numbers
1
All connector
FB 37
numbers
1
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 6
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
SIEMENS AG
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents