Siemens 6RA7086-6KS22 Operating Instructions Manual page 618

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
U671
Source for setting/resetting signal for position acquisition
(2671)
*
Selection of binector whose value is to be used as the setting or resetting
S00
signals.
(B152)
i001:
Reset actual position value 1
i002:
Set actual position value 1
i003:
Reset actual position value 2
i004:
Set actual position value 2
i005:
Reset positional deviation
i006:
Set positional deviation
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
U672
Source for setting values
(2672)
*
S00
Selection of connectors whose values are to be used as setting values
(B152)
i001:
Setting value for position 1
i002:
Setting value for position 2
i003:
Setting value for positional deviation
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U673
Numerator of transformation ratio
(2673)
for actual position value 2
*
U673 must be less than or equal to U674, otherwise F058 is output with
FDS
fault value 14
S00
(B152)
U674
Denominator of transformation ratio
(2674)
for actual position value 2
*
FDS
S00
(B152)
U675
Source for connecting the positional deviation offset
(2675)
*
Selection of the binector whose value connects the offset of the positional
S00
deviation
(B152)
Settings:
0 = Binector B0000
1 = Binector B0001
etc.
U676
Source for positional deviation offset
(2676)
*
Selection of the connector whose value is to be used as the offset of the
S00
positional deviation
(B152)
Settings:
0 = Connector K0000
1 = Connector K0001
etc.
U677
Fixed values for position acquisition
(2677)
*
i001:
LOW word of double-word connector KK9471
S00
i002:
HIGH word of double-word connector KK9471
(B152)
i003:
LOW word of double-word connector KK9472
i004:
HIGH word of double-word connector KK9472
i005:
LOW word of double-word connector KK9473
i006:
HIGH word of double-word connector KK9473
i007:
LOW word of double-word connector KK9474
i008:
HIGH word of double-word connector KK9474
11-154
Value range
[Unit]
Steps
All binector numbers
FB 54
1
[SW 2.0 and later]
All connector
FB 54
[SW 2.0 and later]
numbers
1
-32766 to 32766
FB 54
1
[SW 2.0 and later]
1 to 32767
FB 54
[SW 2.0 and later]
1
All binector numbers
FB 54
[SW 2.0 and later]
1
All connector
FB 54
[SW 2.0 and later]
numbers
1
-32768 to 32767
FB 54
[SW 2.0 and later]
1
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 6
P052 = 2
FS=0
P051 = 40
Type: L2
offline
Ind: 3
P052 = 2
FS=
P051 = 40
i001: 9471
offline
i002: 9472
i003: 9473
Type: L2
Ind: 4
P052 = 2
FS=10000
P051 = 40
Type: I2
off-line
Ind: 4
P052 = 2
FS=10000
P051 = 40
Type: O2
offline
Ind: none
P052 = 2
FS=0
P051 = 40
Type: L2
offline
Ind: none
P052 = 2
FS=9474
P051 = 40
Type: L2
offline
Ind: 8
P052 = 2
FS=0
P051 = 40
Type: I2
offline
SIEMENS AG
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents