Siemens 6RA7086-6KS22 Operating Instructions Manual page 475

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
P044
Connector display:
*
i001:
Selection of connector displayed in r043.01
i002:
Selection of connector displayed in r043.02
(G121)
i003:
Selection of connector displayed in r043.03
i004:
Selection of connector displayed in r043.04
i005:
Selection of connector displayed in r043.05
i006:
Selection of connector displayed in r043.06
i007:
Selection of connector displayed in r043.07
r045
Binector display:
i001:
Display of binector selected in P046.01
(G121)
i002:
Display of binector selected in P046.02
i003:
Display of binector selected in P046.03
i004:
Display of binector selected in P046.04
P046
Binector display:
*
i001:
Selection of binector displayed in r045.01
i002:
Selection of binector displayed in r045.02
(G121)
i003:
Selection of binector displayed in r045.03
i004:
Selection of binector displayed in r045.04
r047
Display of fault diagnostic memory
Provides more detailed information about the cause of a fault after activation
of a fault message (see Section 10).
i001
Word 1 (fault value)
i002
Word 2
...
i016
Word 16 (fault number)
r048
Hours run
Display of time (hours) in which drive has been operating in states I, II or - -.
(G189)
All times of ≥ approx. 0.1 s are included in the count.
r049
Fault time
Display of time at which the current fault, and the last 7 acknowledged
(G189)
faults, were activated.
i001:
Current fault
st
i002:
1
acknowledged fault
nd
i003:
2
acknowledged fault
rd
i004:
3
acknowledged fault
th
i005:
4
acknowledged fault
th
i006:
5
acknowledged fault
th
i007:
6
acknowledged fault
th
i008:
7
acknowledged fault
P050
Language
*
Language of plaintext display on optional OP1S operator panel and in
DriveMonitor PC service routine
0:
German
1:
English
2:
Spanish
3:
French
4:
Italian
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
hours
hours
hours
hours
hours
hours
hours
hours
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 7
numbers
FS=0
1
Type: L2
0 to 1
Ind: 4
Type: O2
All binector numbers
Ind: 4
1
FS=0
Type: L2
0 to 65535
Ind: 16
1
Type: O2
0 to 65535
Ind: None
[hours]
Type: O2
1 hour
0 to 65535
Ind: 8
[hours]
Type: O2
1 hour
0 to 4
Ind: None
1
FS=0
Type: O2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Online
P052 = 3
P052 = 3
P051 = 40
Online
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P051 ≥ 0
Online
11-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents