Siemens 6RA7086-6KS22 Operating Instructions Manual page 534

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
P646
Source for enable signal for ramp-up integrator switchover
*
Selection of binector to control enabling of the ramp-function integrator
BDS
switchover function.
(G136)
0 = binector B0000
1 = binector B0001
etc.
P647
Source for enable signal for ramp-function generator tracking
*
BDS
Selection of binector to control enabling of the ramp-function generator
tracking function.
(G136)
0 = binector B0000
1 = binector B0001
etc.
11.36 Control word, status word
Selection of sources of control words 1 and 2
P648
Source for control word 1
*
Selection of connector to act as the source for control word 1.
BDS
0
= connector K0000
(G180)
...
8
= connector K0008
9
= parameters P654 to P675 are effective
(every individual bit of control word 1 is input by a binector)
10 = connector K0010
etc.
P649
Source for control word 2
*
Selection of connector to act as the source for control word 2.
BDS
0
= connector K0000
(G181)
...
8
= connector K0008
9
= parameters P676 to P691 are effective
(every individual bit of control word 2 is input by a binector)
10 = connector K0010
etc.
Display of control words 1 and 2
r650
Display of control word 1
Mode of representation on operator panel (PMU):
(G180)
Segments 0 to 15 correspond to bits 0 to 15 of the control word
Segment ON:
Segment OFF:
r651
Display of control word 2
Mode of representation on operator panel (PMU):
(G181)
Segments 0 to 15 correspond to bits 16 to 31 of the control word
Segment ON:
Segment OFF:
11-70
15
14
13
12
11
10
9
7
6
5
4
3
2
1
Corresponding bit is in log. "1" state
Corresponding bit is in log. "0" state
15
14
13
12
11
10
9
7
6
5
4
3
2
1
Corresponding bit is in log. "1" state
Corresponding bit is in log. "0" state
Value range
[Unit]
Steps
All binector numbers
1
All binector numbers
[SW 2.1 and later]
1
All connector
numbers
1
All connector
numbers
1
8
0
8
0
No. indices
Factory
setting
Type
Ind: 2
FS=1
Type: L2
Ind: 2
FS=1
Type: L2
Ind: 2
FS=9
Type: L2
Ind: 2
FS=9
Type: L2
Ind: None
Type: V2
Ind: None
Type: V2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P052 = 3
6RX1700-0AD76