Siemens 6RA7086-6KS22 Operating Instructions Manual page 583

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
Connector changeover switches
Depending on the state of the control signal, one of the two input quantities is applied to the output (connector):
Control signal = 0:The input quantity selected in index i001 is applied to the output
Control signal = 1: The input quantity selected in index i002 is applied to the output
Connector changeover switch 1 (output = K9210)
U240
Source for input quantities
(2240)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B150)
U241
Source for control signal
(2241)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B150)
Connector changeover switch 2 (output = K9211)
U242
Source for input quantities
(2242)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B150)
U243
Source for control signal
(2243)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B150)
Connector changeover switch 3 (output = K9212)
U244
Source for input quantities
(2244)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B150)
U245
Source for control signal
(2245)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B150)
Connector changeover switch 4 (output = K9213)
U246
Source for input quantities
(2246)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B150)
U247
Source for control signal
(2247)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B150)
Connector changeover switch 5 (output = K9214)
U248
Source for input quantities
(2248)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B150)
U249
Source for control signal
(2249)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B150)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
All connector
FB 90
numbers
1
All binector numbers
FB 90
1
All connector
FB 91
numbers
1
All binector numbers
FB 91
1
All connector
FB 92
numbers
1
All binector numbers
FB 92
1
All connector
FB 93
numbers
1
All binector numbers
FB 93
1
All connector
FB 94
numbers
1
All binector numbers
FB 94
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
11-119