Siemens 6RA7086-6KS22 Operating Instructions Manual page 532

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
P633
Source for variable negative limitation at ramp-function generator
*
output
Selection of connectors to be injected at the variable negative limitation at
(G137)
the ramp-function generator output (setpoint limitation).
0
= connector K0000
...
8
= connector K0008
= value as set in parameter P632 ∗ ( − 1)
9
10 = connector K0010
etc.
P634
Source for limitation input at ramp-function generator output
*
Selection of connectors which must be added up to provide the limitation
input at the ramp-function generator output (setpoint limitation).
(G137)
0 = connector K0000
1 = connector K0001
etc.
P635
Source for ramp-function generator setpoint
*
Selection of connector to be injected as the ramp-function generator
FDS
setpoint
0 = connector K0000
(G135)
1 = connector K0001
etc.
P636
Source for reduction signal for ramp-function generator times
*
Selection of connector to be injected as the reduction signal for the ramp-
function generator times
(G136)
i001 acts on ramp-up and ramp-down time (P303, P304)
i002 acts on lower and upper transition roundings (P305, P306)
i003 acts on ramp-up time (P303)
i004 acts on ramp-down time (P304)
i005 acts on lower transition rounding (P305)
i006 acts on upper transition rounding (P306)
0 = connector K0000
1 = connector K0001
etc.
P637
Source for selection of "Ramp-function generator setting 2"
*
Selection of binector to control switchover to "Ramp-function generator
BDS
setting 2".
With a log. "1" signal at the binector, ramp-function generator parameter set
(G136)
2 (P307 - P310) is selected. This function has a higher priority than the
ramp-up integrator function.
0 = binector B0000
1 = binector B0001
etc.
P638
Source for selection of "Ramp-function generator setting 3"
*
Selection of binector to control switchover to "Ramp-function generator
BDS
setting 3".
With a log. "1" signal at the binector, ramp-function generator parameter set
(G136)
3 (P311 - P314) is selected. This function has a higher priority than the
ramp-up integrator function.
0 = binector B0000
1 = binector B0001
etc.
11-68
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 4
numbers
FS=9
1
Type: L2
All connector
Ind: 2
numbers
FS=
1
i001: 190
i002: 0
Type: L2
All connector
Ind: 4
numbers
FS=194
1
Type: L2
All connector
Ind: 6
numbers
FS=1
1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
6RX1700-0AD76