Parameter list
PNU
Description
11.76 Setpoint reduction
U607
Source for activation of the setpoint reduction
(2607)
0 = Binector B0000
*
1 = Binector B0001
BDS
etc.
0
Setpoint reduction active
(G135)
The Setpoint (before the ramp-function generator) is multiplied
by the factor set in parameter U608
1
No setpoint reduction
U608
Multiplier for speed setpoint on activation of the setpoint reduction[SW
(2608)
1.6 and later]
FDS
(G135)
11.77 Definition of the function of inputs and outputs
U616
Control word for input "E stop" (term. 105 to 108)
(2616)
0 = E stop has same effect as OFF2
1 = E stop immediately cancels the firing pulse chain (without waiting for
I = 0 and without outputting α
(G117)
11.78 Definition of the function of the relay output at terminals 109 / 110
U619
Source for the relay output "line contactor ON" (terminals 109 / 110)
(2619)
*
0 = Binector B0000
BDS
1 = Binector B0001
etc.
(G117)
124 = Main contactor ON
11.79 Starting pulse – Speed controller
(See also Chapter 8 Function Diagram Sheet G150)
Starting pulse (integrator setting value for the speed controller)
U651
(2651)
FDS
(G150)
U652
Multiplier for starting pulse with neg. setpoint
(2652)
if the starting pulse acc. to U651 is also used for pos. setpoint
FDS
(G150)
U653
Starting pulse with neg. setpoint
(2653)
FDS
(G150)
U655
Source for Starting pulse
(2655)
0 = Connector K0000
*
1 = Connector K0001
(G150)
etc.
U656
Source for starting pulse with neg. setpoint
(2656)
0 = Connector K0000
*
1 = Connector K0001
(G150)
etc.
U657
Source for switchover starting pulse for pos./neg. setp.
(2657)
*
0 = Binector B0000
BDS
1 = Binector B0001
(G150)
etc.
11-152
[SW 1.6 and later]
[SW 2.0 and later]
)
w
[SW 1.7 and later]
[SW 1.7 and later]
[SW 1.7 and later]
[SW 1.7 and later] -100.00 to 100.00
[SW 1.7 and later]
[SW 1.7 and later]
[SW 1.7 and later]
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 2
1
FS=1
Type: L2
0.00 to 100.00
Ind: 4
[%]
FS=15.00
0.01%
Type: O2
0 to 1
Ind: none
1
FS=0
Type: O2
All binector numbers
Ind: 2
1
FS=124
Type: L2
-100.00 to 100.00
Ind: 4
[%]
FS=0.00
0.01%
Type: I2
0.00 to 200.00
Ind: 4
[%]
FS=50.00
0.01%
Type: O2
Ind: 4
[%]
FS=0.00
0.01%
Type: I2
All connector
Ind: None
numbers
FS=451
1
Type: L2
All connector
Ind: None
numbers
FS=452
1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40
on-line
P052 = 3
P051 = 40
online
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40
on-line
P052 = 3
P051 = 40
on-line
P052 = 3
P051 = 40
on-line
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40