Parameter list
PNU
Description
n812
Receive data on paralleling interface
(2812)
When U806=1 (master) is selected
i001
Receive data from slave with address 2, word 1
(G195)
...
i005
Receive data from slave with address 2, word 5
i006
Receive data from slave with address 3, word 1
...
i010
Receive data from slave with address 3, word 5
i011
Receive data from slave with address 4, word 1
...
i015
Receive data from slave with address 4, word 5
i016
Receive data from slave with address 5, word 1
...
i020
Receive data from slave with address 5, word 5
i021
Receive data from slave with address 6, word 1
...
i025
Receive data from slave with address 6, word 5
When U806=2 to 6 (slave) is selected:
i001
Receive data from master, word 1
...
i005
Receive data from master, word 5
i006
Not in use
...
i025
Not in use
n813
Transmit data on paralleling interface
(2813)
When U806=1 (master) is selected
i001
Transmit data to slaves, word 1
(G195)
...
i005
Transmit data to slaves, word 5
When U806=2 to 6 (slave) is selected:
i001
Transmit data to master, word 1
...
i005
Transmit data to master, word 5
11.90 Parameters for SIMOREG CM (Control Module)
U819
These parameters have no meaning for SIMOREG DC Master!
The SIMOREG CM (Control Module, control section for converting or
to
upgrading systems) requires these parameters.
U835
(for details see operating instructions for SIMOREG CM, order No.
(2819 to
6RX1700-0BD76)
2835)
11.91 Rated DC current of external field device
U838
Rated DC current of external field device
(2838)
0.00
Parameter not yet set
*
Note:
This parameter is operative only if P082 >= 21.
11-174
Value range
[Unit]
Steps
0000 to FFFFH
1
0 to FFFFH
0.00 to 600.00
[SW 1.9 and later]
[A]
0.01A
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 25
P052 ≥ 0
Type: L2
Ind: 5
P052 ≥ 0
Type: L2
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
on-line
SIEMENS AG
6RX1700-0AD76
Operating Instructions