Siemens 6RA7086-6KS22 Operating Instructions Manual page 556

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
P817
Peer-to-peer 2: Source for data transmission enabling command
0 = binector B0000
(G173)
1 = binector B0001
etc.
P818
Peer-to-peer 3: Source for data reception enabling command
0 = binector B0000
(G174)
1 = binector B0001
etc.
P819
Peer-to-peer 3: Source for data transmission enabling command
0 = binector B0000
(G174)
1 = binector B0001
etc.
11.42 Deactivation of monitoring functions
WARNING
If monitoring functions are deactivated, there may be a risk to the safety of operating personnel or of
substantial property damage if a fault or error actually occurs!
P820
Deactivation of fault messages
*
The numbers of all fault messages to be deactivated must be entered in this
parameter. Fault numbers can be entered in any order. 0 must be entered
for any unused indices of the parameter.
Factory setting:
i001 = 7
i002 = 18
i003 = 31
i004 = 35
i005 = 36
i006 = 37
i007 to i099 = 0
P821
Deactivation of alarms
*
The numbers of all alarm messages to be deactivated must be entered in
this parameter. Alarm numbers can be entered in any order. 0 must be
entered for any unused indices of the parameter.
11.43 Compensation values
r824
A7006 compensation values
These data contain compensation values for the analog section of
electronics board A7006
P825
Offset compensation for actual field current channel
These data contain compensation values for the actual field current sensing
function. They are automatically set during "Restore factory settings"
(P051=21) and during the automatic offset compensation run (P051=22).
11-92
(overvoltage)
(short circuit at binary outputs)
(monitoring of speed controller)
(drive blocked)
(armature current cannot flow)
2
(I
t motor monitoring function has responded)
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: None
1
FS=1
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
All binector numbers
Ind: None
1
FS=1
Type: L2
0 to 147
Ind: 99
1
FS=
see column
on left
Type: O2
0 to 147
Ind: 99
1
FS= 0
Type: O2
0 to 65535
Ind: 10
1
Type: O2
13000 to 25000
Ind: 3
1
FS=19139
Type: O2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P052 = 3
P051 = 40
Online
6RX1700-0AD76