Parameter list
PNU
Description
r036
Display of field current controller setpoint
(G166)
r037
Display of actual EMF value
(G165)
r038
Display of actual armature voltage value
r039
Display of EMF setpoint
(G165)
This parameter displays the EMF setpoint which is applied as the control
quantity in the field-weakening range.
This value is calculated from:
– Imotor
Umotor
rated
r040
Display of limitations:
Representation on operator panel (PMU):
Segment ON:
Segment OFF:
Segment or bit
0
1
2
3 ....... Negative current limit (armature) reached (K0132)
4 ....... Negative maximum speed reached (P513)
5 ....... Negative torque limit reached (B0203)
6 ....... Neg. limitation at ramp generator output reached (K0182)
7 ....... Neg. limitation at ramp generator input reached (K0197)
8 ....... α G limit (field) reached (P250)
9 ....... Positive current limit (field) reached (K0273)
10 ....... α G limit (armature) reached (P150)
11 ....... Positive current limit (armature) reached (K0131)
12 ....... Positive maximum speed reached (P512)
13 ....... Positive torque limit reached (B0202)
14 ....... Pos. limitation at ramp generator output reached (K0181)
15 ....... Pos. limitation at ramp generator input reached (K0196)
Note:
This parameter has the same bit assignments as connector K0810.
Connector and binector displays
r041
High-resolution connector display:
i001:
Display of connector selected in P042.01
(G121)
i002:
Display of connector selected in P042.02
The display value is filtered with a time constant of 300ms (see Section 8,
Sheet G121)
P042
High-resolution connector display:
*
i001:
Selection of connector to be displayed in r041.01
i002:
Selection of connector to be displayed in r041.02
(G121)
The display value is filtered with a time constant of 300ms (see Section 8,
Sheet G121)
r043
Connector display:
i001:
Display of connector selected in P044.01
(G121)
i002:
Display of connector selected in P044.02
i003:
Display of connector selected in P044.03
i004:
Display of connector selected in P044.04
i005:
Display of connector selected in P044.05
i006:
Display of connector selected in P044.06
i007:
Display of connector selected in P044.07
11-10
* RA (= P101 – P100 * P110)
rated
15
14
13
12
11
10
6
4
7
5
3
2
Corresponding limitation is reached
Corresponding limitation is not reached
α W limit (field) reached (P251)
Negative current limit (field) reached (K0274)
α W limit (armature) reached (α W acc. to P151
for continuous current, 165° for discontinuous current)
Speed limiting controller responds (B0201)
Speed limiting controller responds (B0201)
9
8
1
0
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
0.0 to 199.9
Ind: None
[% of P102]
Type: O2
0.1% of P102
-1500.0 to 1500.0
Ind: None
[V]
Type: I2
0.1V
-1500.0 to 1500.0
Ind: None
[V]
Type: I2
0.1V
0.0 to 1500.0
Ind: None
[V]
Type: O2
0.1V
Ind: None
Type: V2
-200.00 to 199.99
Ind: 2
[%]
Type: I2
0.01%
All connector
Ind: 2
numbers
FS=0
1
Type: L2
-200.0 to 199.9
Ind: 7
[%]
Type: I2
0.1%
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P051 = 40