Siemens 6RA7086-6KS22 Operating Instructions Manual page 516

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
11.25 Motorized potentiometer
(see also Section 8, Sheet G126)
P460
Control word for motorized potentiometer ramp-function generator
*
0
The motorized potentiometer ramp generator is bypassed in
FDS
Automatic mode (same effect as for P462 and P463 = 0.01, i.e.
the generator output is made to follow the automatic setpoint
(G126)
without delay)
1
Motorized potentiometer ramp generator is active in Manual and
Automatic modes
P461
Source for setpoint in Automatic mode
*
Selection of the connector to be applied as the Automatic setpoint to the
FDS
ramp-function generator in the motorized potentiometer
(G126)
0 = connector K0000
1 = connector K0001
etc.
P462
Ramp-up time for motorized potentiometer
FDS
(G126)
P463
Ramp-down time for motorized potentiometer
FDS
(G126)
P464
Time difference for dy/dt
Setting of dt for the output of dy/dt at a connector,
FDS
i.e. on K0241 the change in the output quantity (K0240) is output within the
time set in P464, multiplied by the factor set in P465
(G126)
(unit of time setting is [s] if P465=0 or [min] if P465=1)
Example: - The ramp-function generator is currently ramping up with a
ramp-up time of P462=5s, i.e. a ramp-up operation from y=0%
to y=100% takes 5s.
- A time difference dt of P464=2s is set.
- ⇒ A dy/dt of 40% appears at connector K0241 since the dy
within the set dt of 2 s equals (2s/5s)*100%.
P465
Factor of expansion for motorized potentiometer
*
The effective ramp-up time, ramp-down time or time difference for dy/dt is
FDS
the product of the time setting in parameter P462, P463 and P464
respectively, multiplied by the factor set in this parameter.
(G126)
0
Parameters P462, P463 and P464 are multiplied by a factor of 1
1
Parameters P462, P463 and P464 are multiplied by a factor of 60
P466
Source for motorized potentiometer setting value
*
Selection of the connector to be injected as the motorized potentiometer
FDS
setting value
(G126)
0 = connector K0000
1 = connector K0001
etc.
P467
Motorized potentiometer starting value
FDS
Starting value of motorized potentiometer after ON when P473 = 0
(G126)
P468
Setpoint for "Raise motorized potentiometer"
FDS
Motorized potentiometer manual operation: Setpoint for "Raise motorized
(G126)
potentiometer"
P469
Setpoint for "Lower motorized potentiometer "
FDS
Motorized potentiometer manual operation: Setpoint for "Lower motorized
(G126)
potentiometer"
P470
Source for clockwise/counter-clockwise switchover
*
Selection of binector to control "Clockwise/counter-clockwise
BDS
switchover"
("0" state = clockwise).
(G126)
0 = binector B0000
1 = binector B0001
etc.
11-52
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
0 to 1
Ind: 4
1
FS=1
Type: O2
All connector
Ind: 4
numbers
FS=0
1
Type: L2
0.01 to 300.00
Ind: 4
[s]
FS=10.00
0.01s
Type: O2
0.01 to 300.00
Ind: 4
[s]
FS=10.00
0.01s
Type: O2
0.01 to 300.00
Ind: 4
[s]
FS=10.00
0.01s
Type: O2
0 to 1
Ind: 4
1
FS=0
Type: O2
All connector
Ind: 4
numbers
FS=0
1
Type: L2
-199.9 to 199.9
Ind: 4
[%]
FS=0.0
0.1%
Type: I2
-199.99 to 199.99
Ind: 4
[%]
FS=100.00
0.01%
Type: I2
-199.99 to 199.99
Ind: 4
[%]
FS=-100.00
0.01%
Type: I2
All binector numbers
Ind: 2
1
FS=0
Type: L2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
6RX1700-0AD76