3. Configure the host settings.
Table 2-3 Web Host Communication Mode Settings
Host
4. Click Save.
Note: When switching from EVL back to RS-485 mode, all EVL Secondary (DS) controllers
are automatically unregistered from the primary so that they may be used again as
RS-485 DS controllers.
Note: When switching from EVL to RS-485 mode, if the EVL primary can not communicate
with the DS controller, then the DS controller remains an EVL controller until it is set
back to factory defaults.
Note: Switching to RS-485 mode causes deregistration of EVL Secondary controllers from
the primary. Suggestion: Save the configuration database if you might later switch
back to EVL mode.

Configuring for MAXPRO Cloud

1. Navigate to Host/Loop Communications:
2. Click to select MAXPRO Cloud.
40
Setting
Mode
Time Sync
Baud Rate
Dashboard > Panels > Host/Loop Communications, or
Menu > Panel Configuration > Host/Loop Communications.
Description
RS-485 - If Primary provides access to RS-485 Loop.
EVL
- If Primary provides access to Ethernet Virtual Loop.
Synchronizes the primary's time with the secondary panels.
Enabled – Time-synchronizes the loop by automatically
broadcasting the primary's time to secondary panels. Select
from 60-32767 minutes.
Specifies the transmission rate (bits per second) among the
secondary panels on the loop.
Force Baud Reset – Tells all secondary panels to change
to the selected loop baud rate. This saves the user from
having to go to each panel individually.