Restore Entire Loop Detail Chart - Honeywell MPA2C3 User Manual

Access control unit
Hide thumbs Also See for MPA2C3:
Table of Contents

Advertisement

Access control behavior during synchronization

Restore Entire Loop Detail Chart

System Wide Backup Restore
Primary panel to the Secondary panel downloads the following:
Example:
System Restore in the following order with (3) Secondary Panels:
1. The 1st Secondary panel will receive the backup and reboot.
2. The 2nd Secondary panel will receive the backup and reboot
3. The 3rd Secondary panel will receive the backup and reboot.
4. The Primary panel will receive the backup and reboot
Common data includes:
MPA2C3 User Manual
Holidays
Access Group Name (access group details are panel-specific)
Configuration (Site Codes)
Primary Panel access control not affected.
Newly registered secondary panels will show online in Web Interface and will
keep its existing card and common config. Once common data received,
secondary's access control and communication processes stop running and the
existing common data will be overwritten by new one from primary. Once the
common data is received the Secondary panel will reboot.
Approximately 4 minutes for secondary panel access control to function after
registration and synchronization.
Common Data
Panel-specific data
Schedules
Cards
Card Formats
Holidays
Access Group Name (access group details are panel-specific)
Configuration (Site Codes)
131