Honeywell MPA2 Installation Manual

Honeywell MPA2 Installation Manual

Access control unit
Hide thumbs Also See for MPA2:
Table of Contents

Advertisement

MPA2
Access Control Unit
Release 1.0
December 2019
© 2019 Honeywell. All rights reserved.
800-25395 - B

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell MPA2

  • Page 1 MPA2 Access Control Unit Installation Guide Release 1.0 December 2019 © 2019 Honeywell. All rights reserved. 800-25395 - B...
  • Page 2 All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.
  • Page 3 Installing the MPA2 Panels Installing the MPA2 Panels In this manual... Introduction Panel Components and Descriptions Installation System Configuration Hardware Specifications Firmware Specification Basic Standalone Operation Maintenance Troubleshooting Technical Support MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 4 1.2 MPA2 Overview A MPA2 access control is a full-featured two-door web-based access control system. The MPA2 panel includes a built-in web server, built-in Ethernet and USB support, and Power over Ethernet (PoE) capability. You can manage the access control system using either the built-in web browser, MAXPRO®...
  • Page 5 The MPA2 panel consists of a web-browser-enabled controller, a power-over-Ethernet (PoE) power supply, and a battery (MPA2 Standard only). The following figures show the MPA2 panel wiring and components. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 6 Installing the MPA2 Panels Panel Components and Descriptions Figure 1: MPA2 Compact Enclosure Wiring and Components www.honeywell.com...
  • Page 7 Emission compliancy tests have been executed using a ferrite on following RJ45/USB connections (when used): J4 = Main Ethernet; USB2 = Host; J16 = Interface Bus; J17 & J18 = Downstream Bus. See below the ferrite specification: MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 8 Installing the MPA2 Panels Panel Components and Descriptions www.honeywell.com...
  • Page 9 Normally Open or Normally Closed contacts as supervised or non-supervised. All inputs on the Controller Board and eight additional inputs have default functions, but they can be configured for general purpose inputs. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 10 The following figure shows the typical wiring for a supervised and non-supervised inputs. Figure 3: Typical Supervised and Non- Supervised Input Wiring Diagram Standard 2.2K ohm resistors will be used. The MPA2 panel accepts 1K, 2.2K, 4.7K, or 10K ohm values. Note that both resistors must have the same value.
  • Page 11 Installing the MPA2 Panels Panel Components and Descriptions 2.3 MPA2 Access Control Unit The MPA2 panel is a one and two-door access control unit. The following table shows the MPA2 input/output options: Table 3 MPA2 Input/Output Options Future Development You can use the MPA2 panel as a standalone panel with independent card and transaction storage or, with a host software upgrade, as a fully monitored Online access control device.
  • Page 12 Panel Components and Descriptions 2.4 Power Supply The MPA2 Compact can be powered by Power Over Ethernet (PoE). This PoE can supply a total system current of 2300mA @12VDC. However the MPA2 controller board can consume 250 mA of current. This leaves 2050mA of total current for the 12VDC external power.
  • Page 13 Installing the MPA2 Panels Panel Components and Descriptions 2.5 Battery For the MPA2 Standard Enclosure panel, includes one 12 VDC, 7Ah sealed lead-acid battery. The battery provides standby backup power, depending upon system configuration and activity. When AC is lost, the power supply automatically switches to the backup battery for continuous 12VDC power.
  • Page 14 See DIP Switch Settings, page 32. 3. Check all wiring at this time. Improper wiring can cause damage to the MPA2 at power up Caution: and result in a loss of warranty. 4. Apply power to the panel.
  • Page 15 Installing the MPA2 Panels Installation 3.1 Installing the Standard Enclosure Panel Perform the following steps to install the MPA2 Standard Enclosure panel: Use a static strap whenever touching the panel to ensure Warning: protection from Electrostatic Discharge (ESD). 1. (Optional) Remove the green ground wire and the door.
  • Page 16 Installing the MPA2 Panels Installation 2. Install the four power supply screws to mount the PSU to the metal plate: www.honeywell.com...
  • Page 17 PSU terminals (PE, N, L): 4. Fit the three Power Supply Screws through the key holes in the left bottom side of the cabinet, and seat the power supply by pulling down: MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 18 Installing the MPA2 Panels Installation 5. Connect prepared Low Voltage supply cable (RED, BLACK) to the PSU terminals (V+, V-): www.honeywell.com...
  • Page 19 (ORANGE connector) to the MPA2 Main Board: Do not apply power at this time. Be sure the power cable is Warning: disconnected from the external power source before following this step. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 20 Installing the MPA2 Panels Installation 7. Plug in the prepared Tamper connectors (1 = Off Wall tamper, 2 = Panel door tamper): www.honeywell.com...
  • Page 21 Installing the MPA2 Panels Installation 8. Connect the battery: MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 22 Installation 9. Attach the door to the cabinet. 10. Re-connect the green/yellow Ground wire to the cabinet door: 11. Power up the MPA2 Controller Board and configure the system. Refer to the MPA2 Quick Startup Guide (800-25470) for instructions. www.honeywell.com...
  • Page 23 Supervised Device Protocol) is a bi-directional RS485 Multi-drop AES128 Encrypted protocol. The MPA2 provides 2 separate OSDP ports, one for DOOR1 and one for DOOR2. Each port can have 2 OSDP readers connected (Address 00 = Entry reader and Address 01 = Exit reader).
  • Page 24 Installing the MPA2 Panels Installation • OSDP readers address is default (factory) set to '00'. No extra setting needs to be done when using one reader (Entry) and one door configuration. In case of two reader and one door configuration, make sure the Exit reader (Reader B) is address '01'.
  • Page 25 Ethernet Network devices as switches or routers. The following three tables list the factory controller board I/O default settings for door-1 and door-2 configurations. These are the mappings for MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 26 Installing the MPA2 Panels Installation readers, inputs, and outputs. Reader A and Reader B have their own connections but share the same Wiegand communication port using the hold A/B signals. Table 4 shows the input/output factory default wiring for a one-door configuration on the Controller Board.
  • Page 27 • Reader LED, while it is an output, should never be used to control anything other than its associated reader’s LED. • MPA2 supports a variety of Wiegand reader models. Some readers have only one brown wire for LED control; others have two possible LED control inputs--orange for the green LED and brown for the red LED.
  • Page 28 Installing the MPA2 Panels Installation 3.3 Wiring Door Strikes Follow these steps to wire the door strikes to the Controller Board: 1. Use the following figure to locate the door strike terminals on the board and to wire the door strike/mag lock according to the power supply used.
  • Page 29 • For dry configuration types, the power supply must be voltage compatible, listed to UL 294 or UL 609 for Ul installations and CAN/ULC-S318 for ULC installations, and able to supply sufficient backup power. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 30 (Preferably use CAT 7 S/FTP cable) (J16) on the board. Use pin1&2 (TRX+/TRX-) to connect the NX4 I/O boards. Make sure the NX4 I/O boards are powered with an external 24Vdc Power supply. If the MPA2 controller is physically terminating one end of the RS-485 bus line as shown below, S1 positions 5 &...
  • Page 31 3.4.2 RS485 Panel Downstream bus (IN/OUT) J17, J18 The MPA2 panel has a RS-485 downstream bus for connecting downstream panels (MPA2 or NetAXS123). A maximum of 31 MPA2 and/or NetAXS123 downstream panels can be connected. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 32 Use pin1&2 (TRX+/TRX-) to connect the downstream panels. Make sure the downstream panels are powered by their local Power supply. If the MPA2 controller is physically terminating one end of the RS-485 bus Line, S1 positions 7 & 8 need to be set to ON.
  • Page 33 Installing the MPA2 Panels Installation For additional information concerning the Downstream Panel interface, See section Downstream Devices (I/O) MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 34 3.5 Setting DIP Switches and Jumpers 3.5.1 Controller Board DIP Switch and Jumper Settings Figure 8: Controller Board DIP Switch and Jumper Location DIP Switch Settings Use the following (Figure 9) DIP switch configurations to set up your MPA2 panel. www.honeywell.com...
  • Page 35 Installing the MPA2 Panels Installation Table 7 MPA2 SW1 DIP Switch (1-10) Settings MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 36 Installing the MPA2 Panels Installation MPA2 SW1 DIP Switch (1-10) Settings (Continued) DIP Switch 4 (SW1) does NOT require a panel reboot to take effect. This does not affect the USB IP address. If the panel will be configured in EVL Mode, leave S5 through S9 set to factory default.
  • Page 37 7. After the panel comes up, the RUN LED should flash normal. The panel is now reset to the original factory default values. Address 0 is not a valid setting. Note: MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 38 Installation Jumper Settings The MPA2 Controller Board provides four jumper sets, one each for output relay 1, relay AUX 1, output relay 2, relay AUX 2. Each relay has two 3-pin jumpers associated with it. One jumper selects either external power (EXT) or self-wetted (on-board, +12V) power to be applied to the relay contact load.
  • Page 39 Installing the MPA2 Panels Installation MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 40 MPA2 panel. In some applications, the number of system inputs or outputs exceeds the number that is standard on the MPA2 panel. The solution is to add a combination of NX4IN and NX4OUT downstream I/O devices external to the MPA2 enclosure on a dedicated RS-485 Interface bus.
  • Page 41 DIP switch 3. If a NX4IN is configured with an address other than 1 or 2, the MPA2 panel will not communicate with it. Likewise, if a NX4OUT is configured with an address other than 3 through 6, the MPA2 panel will not communicate with it.
  • Page 42 Installing the MPA2 Panels Installation Figure 10: Default Downstream I/O Configuration with Wiring www.honeywell.com...
  • Page 43 Installation 3.7 Communications 3.7.1 USB Communications The MPA2 Controller Board provides a version 2.0 USB port that connects to the web browser or to a MPC/WIN-PAK. The following figure identifies the location of the port on the board. USB communication requires the USB A to MicroUSB B cable.
  • Page 44 Installing the MPA2 Panels Installation 2. Click on the product menu to start the USB driver Install USB Drivers installation wizard. 3. Click to display the Ready to Install the Program screen. Next If confirmation dialog boxes pop up before or during the...
  • Page 45 For login information, go to https://192.168.2.150. 3.7.2 RS-485 Communications If a MPA2 panel is to be placed onto a pre-existing RS-485 dropline loop (NetAXS) it must be setup as the Primary panel. The interface allows the wiring of a Multi-drop communication network of up to 4,000 feet (1200 m) in length.
  • Page 46 Note: N1000-III, N1000-IV, or NS2 are allowed on the same network. If they are added to a network with a MPA2 Primary panel, they will not be able to communicate with the host computer. Figure 11: RS-485 Configuration via MPA2 Primary...
  • Page 47 This configuration supports a total of 31 NetAXS-123 and MPA2 panels per Multidrop line. Each MPA2 panel has a port for an Ethernet TCP/IP interface. The Ethernet TCP/IP interface provides 10/100 MB Ethernet support for each panel. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 48 Installing the MPA2 Panels System Configuration 4.0 System Configuration This section provides wiring diagrams for each of the MPA2 system configurations. 4.1 Ethernet Connection to MPA2 Primary Managing RS485 Loop Figure 12: Ethernet Connection 100 BaseT (CAT 7 S/FTP) 328 Ft. Max. (90 m)
  • Page 49 S8-S9: OFF: 485 Termination OFF S1 7-8: ON: 485 Termination ON NetAXS-123 MPA2 Panel Panel You should ground each MPA2 Standard (Metal) Enclosure panel Note: individually with an Earth Ground. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 50 Installing the MPA2 Panels System Configuration 4.3 RS-485 Loop Connection via MPA2 This loop connection supports a total of 31 MPA2 panels (including the Primary) for each drop line. Figure 14: RS-485 Loop Connection via MPA2 Ethernet RS-485 (4000 Ft. Max.)
  • Page 51 Cable You can connect Secondary panels at both ends of an RS-485 cable via either a MPA2 panel or a PCI-3 device. Figure 15: RS-485 Connection via MPA2 with Secondary Panels at Both Ends Ethernet RS-485 Cable DIP Switch Settings SW5-9: Panel 4,000 ft.
  • Page 52 1. The Network must provide DHCP server (or use dedicated Network configuration with a router, as shown in next section). 2. The Network must provide firewall protection from unauthorized access. 3. EVL connected MPA2 downstream panel communication has not been evaluated by UL. www.honeywell.com...
  • Page 53 SW2: 4-8: OFF SW2: 4-8: OFF Ethernet Connection with EVL Loop on Dedicated Network 1. Router must provide DHCP service. Note: 2. The Router has not been evaluated by UL. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 54 Installing the MPA2 Panels System Configuration 4.7 Ethernet Connection with Ethernet Virtual Loop - Multiple Locations Figure 18: Ethernet Connection with Ethernet Virtual Loop - Multiple Locations Location 1 The network must allow the Primary Terminal in Location 1 to connect to TCP port XXXX in Locations 2 &...
  • Page 55 Primary controller. There is a “Manual Registration” button on the EVL registration screen for this purpose. 6. The Ethernet Switch has not been evaluated by UL. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 56 Installing the MPA2 Panels Hardware Specifications 5.0 Hardware Specifications The specifications in this section apply to both the Standard Enclosure and Compact Enclosure panels. 5.1 Primary input Voltage • The primary input voltage to the powers supply is 100-240VAC, 50/60Hz.
  • Page 57 Installing the MPA2 Panels Hardware Specifications 5.5 PoE Power Limitations If you are using the MPA2 Standard Enclosure and powering the panel with PoE (Power over Ethernet), you must comply with these specifications for proper operation: • A MPA2 panel powered by PoE is 802.3at compliant, providing a maximum of PSE 30W of input power and maximum of 25.5 W of...
  • Page 58 You can minimize these line losses by using either of the following methods: • Connecting the MPA2 panel to the power injector or PoE+ switch with the shortest possible Ethernet cable length. • Amids pan power supply, also known as a PoE power injector, is an additional PoE power.
  • Page 59 European Economic Area (EEA). The CE marking is the manufacturer's declaration that the product meets the requirements of the applicable EC directives MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 60 Installing the MPA2 Panels Hardware Specifications UL (Underwriters Laboratories) is a testing facility for light fixtures (and other electrical devices) that vouches for the safety of the product. UL is one of several companies approved to perform safety testing by the U.S. federal agency Occupational Safety and Health Administration (OSHA).
  • Page 61 30 days only*. 6.2 Firmware Upgrades Panel Requirements MPA2 panels must first be upgraded to the latest release firmware version. Refer to the release notes for more information. The secondary (downstream) EVL panels should be upgraded first Note: and then the primary (Primary) panel(s).
  • Page 62 Installing the MPA2 Panels Basic Standalone Operation 7.0 Basic Standalone Operation 7.1 Card Read / Door Lock Operation 1. Present a card to a reader. 2. The reader sends the card number to a reader input on the panel. 3. The panel searches its database and: •...
  • Page 63 • Change the backup battery every two to two-and-a-half years. • Oil the lock once per year. The power supply contains no serviceable parts. There is no Note: replaceable fuse inside the power supply. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 64 (including the battery), change the switch setting, re-connect the Host RS-485 terminal block, and re-apply the power. The panel Option 1: Set the MPA2 panel’s DIP switch 4 to ON. This will address is default the IP address to 192.168.1.150.
  • Page 65 2 business days. "Schedule Technical Support: • Coordinate a scheduled time that works best for you and your customer. Hours for Scheduled Support are 10AM - 4PM EST. MPA2 Access Control Unit Installation Guide, Document 800-25395 - B...
  • Page 66 Installing the MPA2 Panels Technical Support "How-To Videos: • DIY with videos that address some of the most common questions around our products and solutions. MyWebTech | Customer Portal | https://mywebtech.honeywell.com • "Download Center: Access the Download Center for the latest firmware and software updates •...
  • Page 67 Honeywell Access Systems 135 W. Forest Hill Avenue Oak Creek, WI 53154 United States 800-323-4576 414-766-1798 Fax www.honeywellaccess.com Specifications subject to change without notice. © Honeywell. All rights reserved. Document 800-25395 - Rev B...