Minimizing Bluetooth/Ism Band Network Activity; Auto Reconnect Mode; Maximum Link Attempts - Honeywell 1602-B User Manual

Wireless area-imaging pocket scanner
Table of Contents

Advertisement

Minimizing Bluetooth/ISM Band Network Activity

The settings described below can help you customize the relinking behavior of the wireless area-imaging system to obtain the
best compromise between convenience and low interference.
Note: ISM band refers to the 2.4 to 2.48 GHz frequency band used by wireless networks, cordless phones, and Bluetooth.

Auto Reconnect Mode

Auto Reconnect controls whether or not the scanner automatically begins the relink process when a loss of connection is
detected. When the Auto Reconnect On bar code is scanned, the scanner begins the relink process immediately, without
user intervention. Default = Auto Reconnect On.
* Auto Reconnect On
Note: If you are connecting to a Bluetooth Interface Module, set Auto Reconnect to Off.
The table below shows the results of the Auto Reconnect On and Off settings:
Event
Scanner out of range
Host reset (firmware upgrade or
power cycle)
Scanner power down due to
Power Time-Out Timer setting
(see
page
3-9)
Scanner reset due to firmware
upgrade
Scanner reset due to battery
change

Maximum Link Attempts

The Maximum Link Attempts setting controls the number of times the scanner tries to form a connection with a host.
During the connection setup process, the scanner transmits in order to search for and connect to a host. In order to prevent
continuous transmissions that could interfere with other users of the ISM band, the number of attempts to connect is limited
by this setting. After the maximum number of attempts is reached, the scanner will not attempt to reconnect to a host.
Pressing the scan button, scanning a host linking bar code, or pairing the scanner with a host resets the attempt count and
the scanner will again try to link.
3 - 2
The HEC and TEC codes identified in this watermark supersede any conflicting HEC or TEC codes displayed in the drawing.
Auto Reconnect On
Relink occurs automatically. If maximum
number of link attempts is unsuccessful,
then the scanner must be relinked by
either pressing the scan button or
relinking the scanner to the host. See
Pairing the Scanner
®
with Bluetooth
Devices
on page 1-3.
Also see
Maximum Link Attempts
page 3-2.
Scanner behaves as if out of range.
Scan button must be pressed.
Relink occurs automatically.
Relink occurs automatically.
Auto Reconnect Off
Auto Reconnect Off
The scanner is relinked by pressing
the scan button or relinking to the
host.
on
No attempt to relink made while host
is powered off. Scan button must be
pressed to initiate relinking.