Clear All Suffixes
Function Code Transmit
When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function
code to the terminal. Charts of these function codes are provided in
page
A-3. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.
Default = Enable.
* Enable
Intercharacter, Interfunction, and Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage
delays slow the transmission of data, increasing data integrity.
Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each
character of scanned data. Scan the Intercharacter Delay bar code below, then scan the number of 5ms delays, and the
Save bar code using the
To remove this delay, scan the Intercharacter Delay bar code, then set the number of delays to 0. Scan the Save bar code
using the
Programming Chart
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed after the transmission of a particular
character of scanned data. Scan the Delay Length bar code below, then scan the number of 5ms delays, and the Save
bar code using the
The HEC and TEC codes identified in this watermark supersede any conflicting HEC or TEC codes displayed in the drawing.
Programming Chart
inside the back cover of this manual.
Prefix
inside the back cover of this manual.
Programming Chart
inside the back cover of this manual.
ASCII Conversion Chart (Code Page 1252)
Scanned Data
Suffix
1
2
3
4
5
Intercharacter Delay
Intercharacter Delay
Clear One Suffix
starting on
Disable
5 - 3