Scanner to Bioptic Communication

The following Scanner to Bioptic Communication settings should only be used when connecting through an Access Point.
They are used to set up communication between Honeywell scanners and bioptic scanners.
Note: The scanner's baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate
with a bioptic scanner. See "RS232 Modifiers" on page 2-18, and
information.
Scanner-Bioptic Packet Mode
Packet Mode On must be scanned to set the scanner's format so it is compatible with a bioptic scanner. Default =
Packet Mode Off.
* Packet Mode Off
Scanner-Bioptic ACK/NAK Mode
Bioptic ACK/NAK On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each
packet is sent. The Scanner-Bioptic ACK/NAK Timeout (below) controls how long the scanner will wait for a response.
Default = Bioptic ACK/NAK Off.
* Bioptic ACK/NAK Off
Scanner-Bioptic ACK/NAK Timeout
This allows you to set the length (in milliseconds) for a timeout for a bioptic scanner's ACK/NAK response. Scan the
bar code below, then set the timeout (from 1-30,000 milliseconds) by scanning digits from the inside back cover, then
scanning Save. Default = 5100.
2 - 22
The HEC and TEC codes identified in this watermark supersede any conflicting HEC or TEC codes displayed in the drawing.
RS232 Timeout
ACK/NAK Timeout
on page 2-21 for further
Packet Mode On
Bioptic ACK/NAK On