Multiple Symbols; No Read - Honeywell 1602-B User Manual

Wireless area-imaging pocket scanner
Table of Contents

Advertisement

When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is turned on.
Required

Multiple Symbols

When this programming selection is turned On, it allows you to read multiple symbols with a single press of the scanner's but-
ton. If you press and hold the button, aiming the scanner at a series of symbols, it reads unique symbols once, beeping (if
turned on) for each read. The scanner attempts to find and decode new symbols as long as the scan button is pressed. When
this programming selection is turned Off, the scanner will only read the symbol closest to the aiming beam. Default = Off.
On

No Read

With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data
Window (see page 8-3), an "NR" appears when a code cannot be read. If No Read is turned Off, the "NR" will not appear.
Default = Off.
On
If you want a different notation than "NR," for example, "Error," or "Bad Code," you can edit the output message (see
Formatting
beginning on page 6-1). The hex code for the No Read symbol is 9C.
4 - 18
The HEC and TEC codes identified in this watermark supersede any conflicting HEC or TEC codes displayed in the drawing.
*Off
On/Not Required
* Off
* Off