Guidelines for Connecting Local Alarm Input Ports

Ground alarm inputs. Choose from normally open (NO) or normally closed (NC).
Connect the COM end and GND end of the alarm detector in parallel. Supply external
power to the alarm detector.
Connect the ground of the NVR and the ground of the alarm detector in parallel.
Connect the NO/NC port of the alarm sensor to the NVR alarm input.
Use the same ground as the NVR if you are supplying external power to the alarm device.

Guidelines for Connecting Alarm Output Ports

Provide external power to external alarm device.
To prevent overloading, carefully review the following relay specifications:
Table 14-2 Guidelines for Connecting Alarm Output Ports
Material
Rating
(Resistance
Load)
242
Nickel/silver contacts with gold
plating
Rated switch capacity
Maximum switch power
Maximum switch voltage
30 V DC 1A; 125 V AC 0.5A
62.5 V AC, 30 W
125 V AC; 60 V DC