CHAPTER 12 MAINTENANCE AND SERVICING
No.
Work
10
Press the test switch for the
leakage breaker to make
sure that it operates
normally.
After making a check, turn
off the power switch, and
shift the lever to ON; then,
turn on the power switch.
Check to make
sure
grounding wire is
c o n n e c t e d
properly. If it is not
c o n n e c t e d
properly,
leakage breaker
may fail to operate
in the presence of
electrical leakage.
12-5a
COPYRIGHT © 2002 CANON INC.
Press the test switch when the
power switch is at ON and, in
addition, the lever [1] of the
leakage breaker is at ON. If
normal, the lever will shift to
OFF to cut the power. If the
lever does not shift to OFF,
replace the leakage breaker.
(Pay attention to its
orientation during
replacement.) After
that
the
replacement, make a check
one again.
the