CHAPTER 11 INSTALLATION
3) See that the developing assembly is
locked in position and the screw inside it
starts to rotate (about 10 sec).
Be sure to wait until the
selected
assembly is locked in
position.
4) Fit the starter developer supply funnel that
comes with the copier* in the supply
mouth of the developing assembly, and
hold it in place.
* Do not use the supply funnel, whose
mouth is too small.
• Be sure to try one color at one time.
5) Take out the M,C,Y and Bk starter bottles,
and shake them well. Peel off the seals.
6) Pour the starter developer into the
developing assembly.
• Try tilting the starter developer bottle
gradually to avoid spilling.
7) When done, press the Stop key to stop the
operation.
• The copier will indicate 'READY'.
11-20
COPYRIGHT © 2002 CANON INC.
developing
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
Starter developer supply flannel
Figure 11-229
Figure 11-230