CHAPTER 6 IMAGE FORMATION SYSTEM
5) Remove the screw [5] (one each), and
remove the end felt [6].
G. Pre-Cleaning Sensor
Assembly No. 2 Scoop-Up
Sheet Assembly
1. Replacing the No. 2 Scoop-Up
Sheet Assembly
1) Remove the pre-cleaning sensor assembly
and two screws; then, remove the No. 2
static eliminator..
2) Remove the screw [1], and detach the pre-
cleaning sensor [2].
3) Mount the pre-cleaning sensor to the new
No. 2 scoop-up sheet plate.
4) Mount the pre-cleaning sensor assembly
and the No. 2 static eliminator to the
copier.
2. Points to Note When Handling the
Pre-Cleaning Sensor Assembly
If you have removed or replaced the pre-
cleaning sensor assembly, be sure to perform
the following:
1) Dry wipe the window of the pre-cleaning
sensor, and mount it; at this time, take
care not to damage the photosensitive
drum by the edge of the sensor assembly.
2) Turn on the power switch so that the
copier will be in standby state.
3) Select and execute FUNCTION>SENS-
ADJ>CLN-OFST.
4) Record the value of ADJUST>SENS-
ADJ>CLN-TH, CLN-TMP on the service
label behind the right front cover.
6-80
COPYRIGHT © 2002 CANON INC.
[5]
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
[6]
Figure 6-672
[2]
[1]
Figure 6-673
[6]
[5]
[1]