Mitsubishi Electric FR-A700 Technical Manual page 97

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

3) Position control
Positioning unit
MELSEQ-Q QD75P1
CLEAR
PULSE F
PULSE R
CLEAR COM
PULSE COM
RDY COM
READY
Torque limit command
*1 For the fan of the 7.5kW or less dedicated motor, the power
supply is single phase (200V/50Hz, 200 to 230V/60Hz).
*2 Assign OH (external thermal input) signal to the terminal
CS. ([Pr. 186 = 7])
Connect a 2W1kΩ resistor between terminals PC and CS (OH).
Install the resistor pushing it against the bottom part of the
terminal block so as to avoid a contact with other cables.
Refer to page 37 for details of [Pr. 186 CS terminal function
selection].
*3 The pin number differs according to the encoder used.
Position control by pulse train input is properly performed
even without connecting Z phase.
*4 The encoder should be coupled on the same axis with the
motor shaft without any mechanical looseness. Speed ratio
should be 1:1.
*5 Earth (Ground) the shielded cable of the encoder cable to
the enclosure with a P clip, etc. (Refer to page 91)
*6 For the complementary, set the terminating resistor
selection switch to OFF position. (Refer to page 86)
Vector Control Dedicated Motor (SF-V5RU), 12V Complementary
Three-phase AC
power supply
FLS
RLS
DOG
STOP
Forward stroke end
Reverse stroke end
Pre-excitation (servo on)
Clear signal
Pulse train
Sign signal
24VDC power supply
COM
Preparation ready signal
(+)
( ± 10V)
(-)
CS(OH)
PC
Control circuit
terminal block
Resistor (2W1kΩ)
*1
Three-phase AC
power supply
MCCB
R/L1
Inverter
S/L2
T/L3
PC
External thermal
CS(OH)
relay input *2
SD
STF
FR-A7AP
STR
PA1
PA1
LX *
9
PA2
PA2
CLR
*9
PB1
PB1
JOG
*10
PB2
PB2
Differential
NP *
9
PZ1
PZ1
line driver
PC
PZ2
PZ2
SE
Complementary
PG
Terminating
SD
resistor
PG
ON
RDY
*11
SD
5
*6 *8
OFF
1
*7 A separate power supply of 5V/12V/15V/24V is necessary
according to the encoder power specification.
When performing encoder feedback control and vector
control together, an encoder and power supply can be
shared.
*8 Refer to page 88 for terminal compatibility of the FR-JCBL,
FR-V7CBL and FR-A7AP.
*9 Assign the function using [Pr. 178 to Pr. 184, Pr. 187 to Pr. 189
Input terminal function selection].
*10When position control is selected, terminal JOG function is
made invalid and conditional position pulse train input
terminal becomes valid.
*11Assign the function using [Pr. 190 to Pr. 194 Output terminal
function selection].
90
SPECIFICATIONS
MCCB
SF-V5RU
A
B
FAN
C
U
U
V
V
IM
W
W
E
Earth
(ground)
Thermal
protector
2W1kΩ
G1
G2
*3
A
B
C
D
Encoder
F
G
S
R
*5
12VDC
(-)
(+)
power supply
*4
*7