Mitsubishi Electric FR-A700 Technical Manual page 128

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

[Pr.]
Name
Stall prevention operation level
22
0 to 400%
(torque limit level)
Stall prevention operation level
23
0 to 200%, 9999
compensation factor at double speed
24
Multi-speed setting (speed 4)
0 to 400Hz, 9999
25
Multi-speed setting (speed 5)
0 to 400Hz, 9999
26
Multi-speed setting (speed6)
0 to 400Hz, 9999
27
Multi-speed setting (speed7)
0 to 400Hz, 9999
28
Multi-speed input compensation selection
0, 1
29
Acceleration/deceleration pattern selection 0 to 5
30
Regenerative function selection
0, 1, 2, 10, 11, 20, 21
31
Frequency jump 1A
0 to 400Hz, 9999
32
Frequency jump 1B
0 to 400Hz, 9999
33
Frequency jump 2A
0 to 400Hz, 9999
34
Frequency jump 2B
0 to 400Hz, 9999
35
Frequency jump 3A
0 to 400Hz, 9999
36
Frequency jump 3B
0 to 400Hz, 9999
37
Speed display
0, 1 to 9998
41
Up-to-frequency sensitivity
0 to 100%
42
Output frequency detection
0 to 400Hz
Output frequency detection for reverse
43
0 to 400Hz, 9999
rotation
44
Second acceleration/deceleration time
0 to 3600/360s
45
Second deceleration time
0 to 3600/360s, 9999
46
Second torque boost
0 to 30%, 9999
47
Second V/F (base frequency)
0 to 400Hz, 9999
48
Second stall prevention operation current
0 to 220%
Second stall prevention operation
49
0 to 400Hz, 9999
frequency
50
Second output frequency detection
0 to 400Hz
0 to 500A, 9999/
51
Second electronic thermal O/L relay
0 to 3600A, 9999
0, 5 to 14, 17 to 20, 22 to 25,
52
DU/PU main display data selection
32 to 35, 50 to 57, 100
1 to 3, 5 to 14, 17, 18, 21, 24,
54
FM terminal function selection
32 to 34, 50, 52, 53
55
Frequency monitoring reference
0 to 400Hz
56
Current monitoring reference
0 to 500/0 to 3600A
0, 0.1 to 5s, 9999/
57
Restart coasting time
0, 0.1 to 30s, 9999
58
Restart cushion time
0 to 60s
59
Remote function selection
0, 1, 2, 3
60
Energy saving control selection
0, 4
0 to 500A, 9999/
61
Reference current
0 to 3600A, 9999
62
Reference value at acceleration
0 to 220%, 9999
63
Reference value at deceleration
0 to 220%, 9999
64
Starting frequency for elevator mode
0 to 10Hz, 9999
65
Retry selection
0 to 5
Stall prevention operation reduction starting
66
0 to 400Hz
frequency
67
Number of retries at fault occurrence
0 to 10, 101 to 110
68
Retry waiting time
0 to 10s
69
Retry count display erase
0
70
Special regenerative brake duty
0 to 30%/0 to 10%
PARAMETER
Minimum Setting
Refer to
Setting Range
Initial Value
Increments
0.1%
150%
283, 335
0.1%
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
1
0
1
0
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
0.01Hz
9999
1
0
0.1%
10%
0.01Hz
6Hz
0.01Hz
9999
0.1/0.01s
5s
0.1/0.01s
9999
0.1%
9999
0.01Hz
9999
0.1%
150%
335, 396
0.01Hz
0Hz
0.01Hz
30Hz
0.01/0.1A
9999
*2
*2
1
0
1
1
0.01Hz
60Hz
Rated inverter
0.01/0.1A
*2
*2
current
0.1s
9999
367, 416
*2
0.1s
1s
367, 416
1
0
1
0
0.01/0.1A
9999
241, 249
*2
*2
0.1%
9999
0.1%
9999
0.01Hz
9999
1
0
0.01Hz
60Hz
1
0
0.1s
1s
1
0
0.1%
0%
*2
122
[Pr.]
Option
Page
22
335
23
216
24
216
25
216
26
216
27
227
28
238
29
331
30
233
31
233
32
233
33
233
34
233
35
233
36
343
37
70
41
70
42
70
43
234
44
234
45
244
46
244
47
48
335
49
70
50
379
51
345
52
345
54
352
55
352
56
57
58
226
59
250
60
61
241
62
241
63
249
64
376
65
335
66
376
67
376
68
376
69
331
70
Instruction Code
Control Mode-based Correspondence Table
Advanced
Vector control
magnetic
flux
vector
control
16
96
0
×
×
×
×
17
97
0
18
98
0
19
99
0
1A
9A
0
1B
9B
0
×
1C
9C
0
×
1D
9D
0
1E
9E
0
×
1F
9F
0
×
20
A0
0
×
21
A1
0
×
22
A2
0
×
23
A3
0
×
24
A4
0
25
A5
0
×
×
29
A9
0
2A
AA
0
2B
AB
0
2C
AC
0
2D
AD
0
×
×
×
×
2E
AE
0
×
×
×
×
2F
AF
0
×
×
×
30
B0
0
×
×
×
31
B1
0
32
B2
0
33
B3
0
34
B4
0
36
B6
0
37
B7
0
38
B8
0
×
39
B9
0
×
×
×
3A
BA
0
×
3B
BB
0
3C
BC
0
×
×
×
×
3D
BD
0
×
×
3E
BE
0
×
×
×
×
3F
BF
0
40
C0
0
×
×
×
×
×
41
C1
0
×
×
×
42
C2
0
×
43
C3
0
×
44
C4
0
45
C5
0
×
46
C6
0
122
PARAMETER
Real sensorless
vector control
Speed
Torque
control
control
×
×
×
×
2
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents