(2) Displays the set frequency during stop
[Pr. 52 = 100]
When [Pr. 52 = 100], the set frequency monitor is
displayed during a stop and the output frequency
monitor is displayed during operation. (LED of Hz
flickers during stop and is lit during operation.)
When [Pr. 52 = 100], the set frequency to be output at
start is displayed during a stop.
The value of the set frequency is different from what is
displayed when [Pr. 52 = 5] and is calculated considering
the maximum/minimum frequency and frequency jump.
The output frequency at error occurrence is displayed
during an error and the monitor displayed during MRS is
the same as at stop.
During offline auto tuning, the tuning status monitor has
priority.
0
During
running/stop
Output
Output
frequency
frequency
Output
current
Output
voltage
Fault or
alarm
indication
(3)
I/O terminal monitor [Pr. 52 = 55 to 57] of
the operation panel (FR-DU07)
When [Pr. 52 = 55 to 57] , the I/O terminal status can
be monitored on the operation panel (FR-DU07).
The I/O terminal monitor is displayed on the third
monitor. The LED is ON when the terminal is ON, and
the LED is OFF when the terminal is OFF. The center
line of LED is always ON.
On the unit I/O terminal monitor ([Pr. 52 = 55]), the
upper LEDs denote the input terminal status and the
lower the output terminal status.
1)
A700
F700
RM
AU
RES
RH
STOP
MRS
RT
RL
RUN
OL
ABC1
SU
FU
Free
ABC2
IPF
2)
E700
RM
Free
RES
RH
Free
MRS
Free
RL
RUN
Free
Free
ABC
FU
Free
Free
Free
[Pr. 52] Setting
100
During
During
stop
running
Set
Output
frequency
frequency
Output current
Output voltage
Fault or alarm indication
JOG
STF
CS
Input terminal
STR
Center line is always ON
Free
Free Free Free
Output terminal
Free
STF
Free
Input terminal
STR
Center line is always ON
Free
Free
Output terminal
Free Free
3)
D700
RM
Free
RH
Free
RL
Free
RUN
Free
Free
ABC
Free
Free
On the input option (FR-A7AX) terminal monitor ([Pr.
52 = 56*], the decimal point LED of the first digit LED
is ON.
A700
F700
(Built-in options cannot be connected to
X1
X4
X2
X5
X0
X3
X12
X15
X10
X13
X11
X14
On the output option (FR-A7AY, FR-A7AR) terminal
monitor ([Pr. 52 = 57*], the decimal point LED of the
second digit LED is ON.)
A700
F700
(Built-in options cannot be connected to
Y1
Y4
Y2
Y0
Y3
RA3
RA1
RA2
* [Pr. 52 = 56, 57] can be set even if the option is not mounted. The
monitor displays are all OFF status if the option is not mounted.
350
PARAMETER
Free
Free
STF
Free
Free
STR
Center line is always ON
Free
Free
Free
Free Free
Free
E700
X7
X8
X6
X9
Center line is always ON
Free
Free
DY
Free
Free
Free
Decimal point LED of first
digit LED is always ON
E700
Y5
Y6
Center line is always ON
Decimal point LED of second
digit LED is always ON
Input terminal
Output terminal
.)
D700
.)
D700
FR-A7AY
FR-A7AR