2.15.2 Monitor display selection of the DU/PU, terminal FM/AM, terminal AM0/AM1
(FR-A7AY), terminal DA1 (FR-A7AZ) [Pr. 52, 54, 158*, 170, 171, 268, 306*, 310*,
563, 564, 838*, 891*]
The monitor to be displayed on the main screen of the
operation panel (FR-DU07)/parameter unit (FR-PU04/FR-
PU07) can be selected.
[Pr. ]
Name
DU/PU main display
52
*
data selection
frequency)
FM terminal function
54
*
selection
AM terminal function
frequency)
158
*
selection
Analog output signal
306
*
selection
Analog meter voltage
310
*
output selection
DA1 terminal function
838
*
selection
Watt-hour meter
170
clear
Operation hour meter
171
clear
Monitor decimal
268
*
digits selection
Energization time
563
carrying-over times
common
(common)
Initial
Setting Range
Value
0, 5 to 14, 17 to 20, 22 to 25,
A700
32 to 35, 50 to 57, 100
0, 5, 6, 8 to 14, 17, 20, 23 to
0
F700
25, 50 to 57, 100
(output
0, 5, 7 to 12, 14, 20, 23 to
E700
25, 52 to 57, 61, 62, 100
0, 5, 8 to 12, 14, 20, 23 to
D700
25, 52 to 55, 61, 62, 64, 100
1 to 3, 5 to 14, 17, 18, 21,
A700
1
24, 32 to 34, 50, 52, 53
(output
1 to 3, 5, 6, 8 to 14, 17, 21,
F700
24, 50, 52, 53
1 to 3, 5, 7 to 12, 14, 21, 24,
E700
2
52, 53, 61, 62
(output
1 to 3, 5, 8 to 12, 14, 21, 24,
current)
D700
52, 53, 61, 62
2
1 to 3, 5 to 14, 17, 18, 21, 24, 32 to
(output
34, 36, 50, 52, 53
current)
0
10
9999
9999
,
9999
0
9999
0
9999
1
9999
0 to 65535
0
(reading only)
(*[Pr. 838] is not available for
(*[Pr. 158, 838, 891] are not available for
(*[Pr. 158, 306, 310, 838] are not available for
In addition, signal to be output to terminal FM (pulse train
output), AM (analog voltage output), AM0 (FR-A7AY
analog voltage output), AM1 (FR-A7AY
output), and DA1 (FR-A7AZ bipolar analog voltage output)
can be selected.
Description
Selects the monitor to be
displayed on the operation
panel and parameter unit.
Refer to the table on the next
page for monitor description
Select the monitor output to
terminal FM.
Select the monitor output to
terminal AM.
Select monitor to be output to
terminal AM0 and AM1 of the
plug-in option FR-A7AY.
Select the monitor to be output
from terminal DA1 of the plug-
in option FR-A7AZ.
Set 0 to clear the watt-hour
meter monitor.
Set the maximum value when
monitoring from
communication to 0 to
9999kWh.
Set the maximum value when
monitoring from
communication to 0 to
65535kWh.
Set "0" to clear the operation
time monitor.
Setting 9999 has no effect.
Displayed as integral value
Displayed in 0.1 increments.
No function
The numbers of cumulative
energization time monitor
exceeded 65535h is displayed.
Reading only