[Pr.]
Name
Setting Range
Digital position control sudden stop
464
0 to 360.0s
deceleration time
465
First position feed amount lower 4 digits
0 to 9999
466
First position feed amount upper 4 digits
0 to 9999
467
Second position feed amount lower 4 digits 0 to 9999
468
Second position feed amount upper 4 digits 0 to 9999
469
Third position feed amount lower 4 digits
0 to 9999
470
Third position feed amount upper 4 digits
0 to 9999
471
Fourth position feed amount lower 4 digits 0 to 9999
472
Fourth position feed amount upper 4 digits 0 to 9999
473
Fifth position feed amount lower 4 digits
0 to 9999
474
Fifth position feed amount upper 4 digits
0 to 9999
475
Sixth position feed amount lower 4 digits
0 to 9999
476
Sixth position feed amount upper 4 digits
0 to 9999
477
Seventh position feed amount lower 4 digits 0 to 9999
Seventh position feed amount upper 4
478
0 to 9999
digits
479
Eighth position feed amount lower 4 digits 0 to 9999
480
Eighth position feed amount upper 4 digits 0 to 9999
481
Nineth position feed amount lower 4 digits 0 to 9999
482
Nineth position feed amount upper 4 digits 0 to 9999
483
Tenth position feed amount lower 4 digits
0 to 9999
484
Tenth position feed amount upper 4 digits
0 to 9999
Eleventh position feed amount lower 4
485
0 to 9999
digits
Eleventh position feed amount upper 4
486
0 to 9999
digits
487
Twelfth position feed amount lower 4 digits 0 to 9999
488
Twelfth position feed amount upper 4 digits 0 to 9999
Thirteenth position feed amount lower 4
489
0 to 9999
digits
Thirteenth position feed amount upper 4
490
0 to 9999
digits
Fourteenth position feed amount lower 4
491
0 to 9999
digits
Fourteenth position feed amount upper 4
492
0 to 9999
digits
Fifteenth position feed amount lower 4
493
0 to 9999
digits
Fifteenth position feed amount upper 4
494
0 to 9999
digits
495
Remote output selection
0, 1, 10, 11
496
Remote output data 1
0 to 4095
497
Remote output data 2
0 to 4095
499
SSCNET III operation selection
0, 1(10, 11), 9999
Communication error execution waiting
500
0 to 999.8s
time
Communication error occurrence count
501
0
display
Stop mode selection at communication
502
0, 1, 2, 3
error
140
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
0.1s
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
309
1
0
77
1
0
77
1
0
77
1
0
0.1s
0
1
0
1
0
Instruction Code
Control Mode-based Correspondence Table
Advanced
magnetic
[Pr.]
Option
flux
vector
control
464
40
C0
4
×
×
×
×
465
41
C1
4
×
×
466
42
C2
4
×
×
467
43
C3
4
468
44
C4
4
×
×
469
45
C5
4
×
×
×
×
470
46
C6
4
×
×
471
47
C7
4
×
×
472
48
C8
4
473
49
C9
4
×
×
474
4A
CA
4
×
×
×
×
475
4B
CB
4
×
×
476
4C
CC
4
×
×
477
4D
CD
4
478
4E
CE
4
×
×
×
×
479
4F
CF
4
×
×
480
50
D0
4
481
51
D1
4
×
×
482
52
D2
4
×
×
×
×
483
53
D3
4
×
×
484
54
D4
4
×
×
485
55
D5
4
×
×
486
56
D6
4
×
×
487
57
D7
4
×
×
488
58
D8
4
489
59
D9
4
×
×
×
×
490
5A
DA
4
491
5B
DB
4
×
×
×
×
492
5C
DC
4
493
5D
DD
4
×
×
×
×
494
5E
DE
4
495
5F
DF
4
496
60
E0
4
497
61
E1
4
×
×
499
63
E3
4
500
00
80
5
501
01
81
5
502
02
82
5
PARAMETER
Real sensorless
Vector control
vector control
Speed
Torque
control
control
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
140
2
×
×