[Special monitor selection No.]
Refer to page 346 for details of the monitor description
Data
Description
Output frequency/speed
A700 F700
H01
Output frequency/speed
E700 D700
H02
Output current
H03
Output voltage
Frequency setting/speed
A700 F700
H05
Frequency setting/speed
E700 D700
*9*10
Running speed
H06
*8*10
Motor torque
H07
H08
Converter output voltage
H09
Regenerative brake duty
H0A
Electronic thermal relay function load factor
H0B
Output current peak value
H0C
Converter output voltage peak value
H0D
*9*10
Input power
H0E
Output power
H0F
*2
Input terminal status
H10
*3
Output terminal state
H11
*9*10
Load meter
*8*9*10
Motor excitation current
H12
*1
The setting depends on the inverter capacity. (55K or less/75K or more)
*2
Input terminal monitor details
b15
A700
F700
b15
E700
b15
D700
*3
Output terminal monitor details
b15
A700
F700
b15
E700
b15
D700
*4
Details of option input terminal monitor 1 (input terminal status of FR-A7AX)-all terminals are OFF when an option is not fitted
b15
X15
X14
X13
*5
Details of option input terminal monitor 2 (input terminal status of FR-A7AX)-all terminals are OFF when an option is not fitted
b15
*6
Details of option output terminal monitor (output terminal status of FR-A7AY/A7AR)--all terminals are OFF when an option is not fitted.
b15
Increments
0.01Hz/1
*11
0.01Hz/
*12
1(0.001)
0.01A/
*1
0.1A
0.1V
*11
0.01Hz/1
0.01Hz/
*12
1(0.001)
1r/min
0.1%
0.1V
0.1%
0.1%
0.01A/0.1A
0.1V
0.01kWh/
*1
0.1kW
0.01kWh/
0.1kW
*1
0.1%
0.01A/
*1
0.1A
CS
RES
STOP
RES
X12
X11
X10
X9
RA3
Data
*8*9*10
Position pulse
H13
H14
Cumulative energization time
*8*9*10
Orientation status
H16
H17
Actual operation time
H18
Motor load factor
H19
Cumulative power
*8*9*10
Torque command
H20
*8*9*10
Torque current command
H21
H22
*8*9*10
Motor output
*8*9*10
Feedback pulse
H23
*9*10
Power saving effect
H32
H33
*9*10
Cumulative saving power
H34
PID set point
H35
PID measured value
*1
H36
PID deviation
*8*10
H3A
Option input terminal status 1
*8*10
H3B
Option input terminal status 2
*8*10
H3C
Option output terminal status 2
H3D
*7*8
Motor thermal load factor
*7*8
Inverter thermal load factor
H3E
H3F
*7*8*9
Cumulative power 2
H40
*7*8*9
PTC thermistor resistance
MRS
JOG
RH
RM
MRS
RH
RM
RH
RM
ABC2
ABC1
ABC
ABC
X8
X7
X6
X5
RA2
RA1
Y6
Y5
455
PARAMETER
Description
Increments
0.01kWh/
0.1kW
Variable
Variable
*4
*5
*6
0.01kWh
0.01kΩ
RL
RT
AU
STR
RL
STR
RL
STR
FU
OL
IPF
SU
FU
X4
X3
X2
X1
Y4
Y3
Y2
Y1
1h
1h
0.1%
1kWh
0.1%
0.1
*1
0.1%
0.1%
0.1%
0.1%
0.1%
2
b0
STF
b0
STF
b0
STF
b0
RUN
b0
RUN
b0
RUN
b0
X0
b0
DY
b0
Y0