[Pr.]
Name
Setting Range
575
Output interruption detection time
0 to 3600s, 9999
576
Output interruption detection level
0 to 400Hz
577
Output interruption cancel level
900 to 1100%
-
611
Acceleration time at a restart
0 to 3600s, 9999
-
653
Speed smoothing control
0 to 200%
-
665
Regeneration avoidance frequency gain
0 to 200%
872
Input phase loss protection selection
0, 1
Regeneration avoidance operation
882
0, 1, 2
selection
883
Regeneration avoidance operation level
300 to 800V
Regeneration avoidance compensation
885
0 to 10Hz, 9999
frequency limit value
886
Regeneration avoidance voltage gain
0 to 200%
888
Free parameter 1
0 to 9999
889
Free parameter 2
0 to 9999
Cumulative power monitor digit shifted
-
891
0 to 4, 9999
times
C0
FM terminal calibration
-
(900)
*5
C2
Terminal 2 frequency setting bias
0 to 400Hz
frequency
(902)
*5
C3
Terminal 2 frequency setting bias
0 to 300%
(902)
*5
125
Terminal 2 frequency setting gain
0 to 400Hz
frequency
(903)
*5
C4
Terminal 2 frequency setting gain
0 to 300%
(903)
*5
C5
Terminal 4 frequency setting bias
0 to 400Hz
frequency
(904)
*5
C6
Terminal 4 frequency setting bias
0 to 300%
(904)
*5
126
Terminal 4 frequency setting gain
0 to 400Hz
frequency
(905)
*5
C7
Terminal 4 frequency setting gain
0 to 300%
(905)
*5
C22
Frequency setting voltage bias frequency
0 to 400Hz
(922)
(built-in potentiometer)
*4 *5
C23
Frequency setting voltage bias (built-in
0 to 300%
(922)
potentiometer)
*4 *5
C24
Frequency setting voltage gain frequency
0 to 400Hz
(923)
(built-in potentiometer)
*4 *5
C25
Frequency setting voltage gain (built-in
0 to 300%
(923)
potentiometer)
*4 *5
990
PU buzzer control
0, 1
991
PU contrast adjustment
0 to 63
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
0.1s
1s
0.01Hz
0Hz
0.1%
1000%
0.1s
9999
0.1%
0
0.1%
100
1
0
1
0
0.1V
780VDC
0.01Hz
6Hz
0.1%
100%
1
9999
1
9999
1
9999
-
-
0.01Hz
0Hz
0.1%
0%
0.01Hz
60Hz
0.1%
100%
0.01Hz
0Hz
0.1%
20%
0.01Hz
60Hz
0.1%
100%
0.01Hz
0
0.1%
0
0.01Hz
60Hz
0.1%
100%
1
1
1
58
198
Instruction Code
[Pr.]
402
575
4B
402
576
4C
402
577
4D
367
611
0B
433
653
35
340
665
41
380
872
48
340
882
52
340
883
53
340
885
55
340
886
56
388
888
58
388
889
59
345
891
5B
C0
356
5C
(900)
C2
217
5E
(902)
C3
217
5E
(902)
125
217
5F
(903)
C4
217
5F
(903)
C5
217
60
(904)
C6
217
60
(904)
126
217
61
(905)
C7
217
61
(905)
C22
390
16
(922)
C23
390
16
(922)
C24
390
17
(923)
C25
390
17
(923)
389
990
5A
389
991
5B
Control Mode-based
Correspondence Table
General-purpose
V/F control
magnetic-flux
vector control
CB
5
CC
5
CD
5
8B
6
B5
6
C1
6
C8
8
D2
8
D3
8
D5
8
D6
8
D8
8
D9
8
DB
8
DC
1
DE
1
DE
1
DF
1
DF
1
E0
1
E0
1
E1
1
E1
1
96
9
96
9
97
9
97
9
DA
9