(5) Performing Advanced magnetic vector
control by switching between two motors
Turning the RT signal ON allows the second motor to
be controlled.
Set the second motor in [Pr. 450 Second applied motor].
(Initial setting is 9999 (without second applied motor).
Refer to page 266.)
1)
A700
RT Signal is ON
Functions
(Second Motor)
Applied motor
Motor capacity
Number of motor
poles
Speed control gain
Control method
selection
2)
E700
Turning the RT signal ON allows the second motor to
be controlled. Set the second motor in [Pr. 450 Second
applied motor].
Note that control method is not selectable for the
second motor, so the same control method as the
first motor applies. When Advanced magnetic vector
control is selected, use same type of motor for the
first and second motors. Use X18 signal when you
want to use the second motor in V/F control.
RT Signal is OFF
(First Motor)
[Pr. 450]
[Pr. 71]
[Pr. 453]
[Pr. 80]
[Pr. 454]
[Pr. 81]
[Pr. 569]
[Pr. 89]
[Pr. 451]
[Pr. 800]
260