Mitsubishi Electric FR-A700 Technical Manual page 158

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

[Pr.]
Name
Setting Range
495
Remote output selection
0, 1, 10, 11
496
Remote output data 1
0 to 4095
497
Remote output data 2
0 to 4095
Communication error execution waiting
500
0 to 999.8s
time
Communication error occurrence count
501
0
display
Stop mode selection at communication
-
502
0, 1, 2, 3
error
503
Maintenance timer
0 (1 to 9998)
504
Maintenance timer alarm output set time
0 to 9998, 9999
Frequency command sign selection (CC-
541
0, 1
Link)
542
Communication station number (CC-Link)
1 to 64
543
Baud rate (CC-Link)
0 to 4
544
CC-Link extended setting
0, 1, 12, 14, 18
547
USB communication station number
0 to 31
548
USB communication check time interval
0 to 999.8s, 9999
549
Protocol selection
0, 1
NET mode operation command source
550
0, 2, 9999
selection
PU mode operation command source
551
2 to 4, 9999
selection
555
Current average time
0.1 to 1.0s
556
Data output mask time
0.0 to 20.0s
Current average value monitor signal
557
0 to 500A
output reference current
-
563
Energization time carrying-over times
(0 to 65535)
-
564
Operating time carrying-over times
(0 to 65535)
-
571
Holding time at a start
0.0 to 10.0s, 9999
-
611
Acceleration time at a restart
0 to 3600s, 9999
-
653
Speed smoothing control
0 to 200%
-
665
Regeneration avoidance frequency gain
0 to 200%
-
800
Control method selection
20, 30
-
859
Torque current
0 to 500A (0 to ****), 9999
872
Input phase loss protection selection
0, 1
Regeneration avoidance operation
882
0, 1, 2
selection
883
Regeneration avoidance operation level
300 to 800V
Regeneration avoidance compensation
885
0 to 10Hz, 9999
frequency limit value
886
Regeneration avoidance voltage gain
0 to 200%
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
1
0
77
1
0
77
1
0
77
0.1s
0
1
0
1
0
1
0
74
1
9999
74
1
0
1
1
1
0
1
0
1
0
473
0.1s
9999
473
1
0
441, 459
1
9999
436
1
9999
436
0.1s
1s
75
0.1s
0s
75
Rated inverter
0.01A
75
current
1
0
345
1
0
345
0.1s
9999
232
0.1s
9999
367
0.1%
0
433
0.1%
100
340
1
20
252, 258
0.01A (1)
9999
268
*6
*6
1
1
380
1
0
340
400VDC/
0.1V
340
780VDC
*5
0.01Hz
6Hz
340
0.1%
100%
340
182
Control Mode-based Correspondence
Instruction Code
[Pr.]
Option
V/F control
495
5F
DF
4
496
60
E0
4
497
61
E1
4
500
00
80
5
501
01
81
5
502
02
82
5
503
03
83
5
504
04
84
5
541
29
A9
5
542
2A
AA
5
543
2B
AB
5
544
2C
AC
5
547
2F
AF
5
548
30
B0
5
549
31
B1
5
550
32
B2
5
551
33
B3
5
555
37
B7
5
556
38
B8
5
557
39
B9
5
563
3F
BF
5
564
40
C0
5
571
47
C7
5
611
0B
8B
6
653
35
B5
6
665
41
C1
6
×
800
00
80
8
×
859
3B
BB
8
872
48
C8
8
882
52
D2
8
883
53
D3
8
885
55
D5
8
886
56
D6
8
182
PARAMETER
Table
General-
Advanced
purpose
magnetic
magnetic-
flux vector
flux vector
control
control
×
×
×
×
×
×
×
×
×
×
×
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
*9
×
×
×
×
×
×
×
2