[Pr.]
Name
Setting Range
80
Motor capacity
0.1 to 7.5kW, 9999
82
Motor excitation current
0 to 500A, 9999
83
Rated motor voltage
0 to 1000V
84
Rated motor frequency
10 to 120Hz
90
Motor constant (R1)
0 to 50Ω, 9999
96
Auto tuning setting/status
0, 11, 21
117
PU communication station number
0 to 31(0 to 247)
118
PU communication speed
48, 96, 192, 384
119
PU communication stop bit length
0, 1, 10, 11
120
PU communication parity check
0, 1, 2
121
Number of PU communication retries
0 to 10, 9999
122
PU communication check time interval
0, 0.1 to 999.8s, 9999
123
PU communication waiting time setting
0 to 150ms, 9999
124
PU communication CR/LF selection
0, 1, 2
Terminal 2 frequency setting gain
-
125
0 to 400Hz
frequency
Terminal 4 frequency setting gain
-
126
0 to 400Hz
frequency
PID control automatic switchover
127
0 to 400Hz, 9999
frequency
128
PID action selection
0, 20, 21, 40 to 43
129
PID proportional band
0.1 to 1000%, 9999
130
PID integral time
0.1 to 3600s, 9999
131
PID upper limit
0 to 100%, 9999
132
PID lower limit
0 to 100%, 9999
133
PID action set point
0 to 100%, 9999
134
PID differential time
0.01 to 10.00s, 9999
145
PU display language selection
0 to 7
-
146
Built-in potentiometer switching
0, 1
∗4
150
Output current detection level
0 to 200%
151
Output current detection signal delay time
0 to 10s
152
Zero current detection level
0 to 200%
153
Zero current detection time
0 to 1s
-
156
Stall prevention operation selection
0 to 31, 100, 101
-
157
OL signal output timer
0 to 25s, 9999
-
160 Extended function display selection
0, 9999
Frequency setting/key lock operation
-
161
0, 1, 10, 11
selection
Automatic restart after instantaneous
162
0, 1, 10, 11
power failure selection
165
Stall prevention operation level for restart
0 to 200%
Output current detection signal retention
166
0 to 10s, 9999
time
Output current detection operation
167
0, 1
selection
-
168
Parameter for manufacturer setting. Do not set.
-
169
170
Watt-hour meter clear
0, 10, 9999
171
Operation hour meter clear
0, 9999
PARAMETER
Minimum Setting
Refer to
Initial Value
Increments
Page
0.01kW
9999
252, 258
0.01A
9999
0.1V
400V
0.01Hz
60Hz
0.001Ω
9999
1
0
268, 367
1
0
1
192
1
1
1
2
1
1
0.1s
0
1
9999
1
1
0.01Hz
60Hz
0.01Hz
60Hz
0.01Hz
9999
1
0
0.1%
100%
0.1s
1s
0.1%
9999
0.1%
9999
0.01%
9999
0.01s
9999
1
0
1
1
0.1%
150%
0.1s
0s
0.1%
5%
0.01s
0.5s
1
0
0.1s
0s
1
9999
1
0
214, 389
1
1
0.1%
150%
0.1s
0.1s
1
0
1
9999
1
9999
192
Instruction Code
[Pr.]
80
50
268
82
52
268
83
53
268
84
54
268
90
5A
96
60
441
117
11
441
118
12
441
119
13
441
120
14
441
121
15
441
122
16
441
123
17
441
124
18
217
125
19
217
126
1A
402
127
1B
402
128
1C
402
129
1D
402
130
1E
402
131
1F
402
132
20
402
133
21
402
134
22
389
145
2D
390
146
2E
72
150
32
72
151
33
72
152
34
72
153
35
335
156
38
335
157
39
386
160
00
161
01
367
162
02
367
165
05
72
166
06
72
167
07
168
Parameter for manufacturer setting. Do not set.
169
345
170
0A
345
171
0B
Control Mode-based
Correspondence Table
General-purpose
V/F control
magnetic-flux
vector control
D0
0
×
D2
0
×
D3
0
×
D4
0
×
DA
0
E0
0
91
1
92
1
93
1
94
1
95
1
96
1
97
1
98
1
99
1
9A
1
9B
1
9C
1
9D
1
9E
1
9F
1
A0
1
A1
1
A2
1
AD
1
AE
1
B2
1
B3
1
B4
1
B5
1
B8
1
B9
1
80
2
81
2
82
2
85
2
86
2
87
2
8A
2
8B
2
192
PARAMETER
×
×
×
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
*6
×
×
2
×
×
×
×
×
×
×
×
×