Terminal 6 function according to control(FR-A7AZ)
V/F Control,
[ Pr. 406 ]
Advanced
Magnetic Flux
Setting
Vector Control
0
Frequency command
2
—
3
—
Stall prevention
4
operation level input
5
—
6
—
9999
(initial
—
value)
: No function
—
* Function assigned to terminal 1, 2, and 4 inputs become invalid if overlapping function is assigned to terminal 6.
Real Sensorless Vector Control,
Vector Control
Speed control
Torque control
Speed
Speed limit
command
Regenerative
torque limit
—
([Pr. 810 = 1])
Torque command
—
([Pr. 804 = 0])
Torque limit
Torque command
([Pr. 810 = 1])
([Pr. 804 = 0])
Forward/reverse
—
rotation speed limit
([Pr. 807 = 2])
Torque bias
—
([Pr. 840 = 1, 2, 3])
—
—
47
SPECIFICATIONS
Vector Control
Position Control
Speed command and speed
—
limit are not available with
terminal 2.
Regenerative
Regenerative torque limit is not
torque limit
available with terminal 1.
([Pr. 810 = 1])
Torque command is not
—
available with terminal 1.
Stall prevention operation level
input and torque limit are not
Torque limit
available with terminal 1 or 4.
([Pr. 810 = 1])
Torque command is not
available with terminal 1.
Forward/reverse rotation speed
—
limit is not available with
terminal 1.
Torque bias is not available with
—
terminal 1.
—
Terminal 6 is invalid.
Remarks
1