Mitsubishi Electric FR-A700 Technical Manual page 314

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

Types of
Increments
(Operation
Monitor
Motor load
0.1%
factor
0.01kWh/
Cumulative
0.1kWh
*8
power
*6*7
Torque
0.1%
*13
command
Torque current
0.1%
*13
command
0.01kW/
Motor output
0.1kW
*7
Feedback pulse
*3*8
Torque monitor
(driving/
regenerative
polarity
switching)
Power saving
effect
Variable
according to
Cumulative
parameters
*8
saving power
PID set point
0.1%
PID measured
0.1%
value
PID deviation
0.1%
Input terminal
status
Output terminal
status
Option input
terminal status
Option output
terminal status
[Pr. 52] Setting
[Pr. 54]
(FM)
[Pr. 158]
DU
PU
(AM)
[Pr. 306]
main
panel)
[Pr. 310]
monitor
LED
[Pr. 838]
Setting
24
24
×
25
32
32
*15
33
33
*15
34
34
*16
×
35
36
*16 *17
50
50
×
51
52
52
53
53
×
54
×
*1
55
×
*1
×
×
56
×
×
57
Full-scale Value
Displays the output current value in
% on the assumption that the
inverter rated current value is 100%
200%
Monitor value = output current
monitor value/rated inverter current
×100 [%]
Displays cumulative power amount
according to the output power
monitor
Use [Pr. 170] to clear the value.
(Refer to page 351)
Displays torque command value
[Pr. 866]
obtained from vector control
Displays the torque current
[Pr. 866]
command value
Multiplies the motor speed by the
Rated motor
output torque and displays the
capacity
machine output of the motor shaft
end
Displays the number of pulses fed
back from the encoder during one
sampling (displays during a stop).
Outputs the motor torque in bipolar
analog by regarding motor rated
[Pr. 866]
torque as 100%. (0% during V/F
control)
Displays energy saving effect monitor
Inverter capacity
You can change the monitor to
power saving, power saving average
value, charge display and % display
using parameters.
(Refer to page 360 for details)
100%
Displays the set point, measured value
100%
and deviation during PID control (refer
to page 402 for details)
Displays the input terminal ON/OFF
status on the PU.
(Refer to page 350 for the DU
display)
Displays the output terminal ON/OFF
status on the PU.
(Refer to page 350 for the DU
display)
Displays the input terminal ON/OFF
status of digital input option (FR-
A7AX) on the DU (refer to page 350
for details)
Displays the output terminal ON/OFF
status of the digital output option
(FR-A7AY) or relay output option
(FR-A7AR) on the DU (refer to page
350 for details).
348
Available Inverters
Description
A700
PARAMETER
F700
E700
D700

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents