Mitsubishi Electric FR-A700 Technical Manual page 129

Hide thumbs Also See for FR-A700:
Table of Contents

Advertisement

[Pr.]
Name
0 to 8, 13 to 18, 20, 23, 24,
71
Applied motor
30, 33, 34, 40, 43, 44, 50, 53,
54
72
PWM frequency selection
0 to 15/0 to 6, 25
73
Analog input selection
0 to 7, 10 to 17
74
Input filter time constant
0 to 8
Reset selection/disconnected PU detection/
75
0 to 3, 14 to 17
PU stop selection
76
Fault code output selection
0, 1, 2
77
Parameter write selection
0, 1, 2
78
Reverse rotation prevention selection
0, 1, 2
79 Operation mode selection
0, 1, 2, 3, 4, 6, 7
0.4 to 55kW, 9999/
80
Motor capacity
0 to 3600kW, 9999
2, 4, 6, 8, 10, 12, 14, 16, 18,
81
Number of motor poles
20, 9999
0 to 500A, 9999/
82
Motor excitation current
0 to 3600A, 9999
83
Rated motor voltage
0 to 1000V
84
Rated motor frequency
10 to 120Hz
Speed control gain (Advanced magnetic
89
0 to 200%, 9999
flux vector)
0 to 50Ω
90
Motor constant (R1)
0 to 400mΩ, 9999
0 to 50Ω
91
Motor constant (R2)
0 to 400mΩ
0 to 50Ω (0 to 1000mH), 9999/
92
Motor constant (L1)
0 to 3600mΩ (0 to 400mH), 9999
0 to 50Ω (0 to 1000mH), 9999/
93
Motor constant (L2)
0 to 3600mΩ (0 to 400mH), 9999
*2
0 to 500Ω (0 to 100%), 9999/
94
Motor constant (X)
0100Ω (0 to 100%), 9999
95
Online auto tuning selection
0 to 2
96
Auto tuning setting/status
0, 1, 101
100
V/F1(first frequency)
0 to 400Hz, 9999
101
V/F1(first frequency voltage)
0 to 1000V
102
V/F2(second frequency)
0 to 400Hz, 9999
103
V/F2(second frequency voltage)
0 to 1000V
104
V/F3(third frequency)
0 to 400Hz, 9999
105
V/F3(third frequency voltage)
0 to 1000V
106
V/F4(fourth frequency)
0 to 400Hz, 9999
107
V/F4(fourth frequency voltage)
0 to 1000V
108
V/F5(fifth frequency)
0 to 400Hz, 9999
109
V/F5(fifth frequency voltage)
0 to 1000V
110
Third acceleration/deceleration time
0 to 3600/360s, 9999
111
Third deceleration time
0 to 3600/360s, 9999
112
Third torque boost
0 to 30%, 9999
113
Third V/F (base frequency)
0 to 400Hz, 9999
114
Third stall prevention operation current
0 to 220%
115
Third stall prevention operation frequency
0 to 400Hz
116
Third output frequency detection
0 to 400Hz
117
PU communication station number
0 to 31
118
PU communication speed
48, 96, 192, 384
119
PU communication stop bit length
0, 1, 10, 11
120
PU communication parity check
0, 1, 2
121
Number of PU communication retries
0 to 10, 9999
122
PU communication check time interval
0, 0.1 to 999.8s, 9999
123
PU communication waiting time setting
0 to 150ms, 9999
124
PU communication CR/LF selection
0, 1, 2
125 Terminal 2 frequency setting gain frequency 0 to 400Hz
PARAMETER
Minimum Setting
Refer to
Setting Range
Initial Value
Increments
1
0
1
2
*2
1
1
1
1
1
14
1
0
1
0
1
0
1
0
209, 434
252, 258,
0.01/0.1kW
9999
*2
261, 263
*2
252, 258,
1
9999
261, 263
0.01/0.1A
9999
*2
*2
0.1V
200/400V
*5
0.01Hz
60Hz
0.1%
9999
,
9999/
0.001Ω/
9999
0.01mΩ
*2
*2
,
9999/
0.001Ω/
9999
,
9999
0.01mΩ
*2
*2
0.001Ω (0.1mH)/
9999
0.01mΩ (0.01mH)
*2
*2
0.001Ω (0.1mH)/
9999
0.01mΩ (0.01mH)
*2
0.01Ω (0.1%)/
9999
0.01Ω (0.01%)
*2
*2
1
0
1
0
0.01Hz
9999
0.1V
0V
0.01Hz
9999
0.1V
0V
0.01Hz
9999
0.1V
0V
0.01Hz
9999
0.1V
0V
0.01Hz
9999
0.1V
0V
0.1/0.01s
9999
0.1/0.01s
9999
0.1%
9999
0.01Hz
9999
0.1%
150%
0.01Hz
0
0.01Hz
60Hz
1
0
1
192
1
1
1
2
1
1
0.1s
9999
1
9999
1
1
0.01Hz
60Hz
124
[Pr.]
Option
Page
266
71
430
72
217
73
217
74
382
75
378
76
384
77
385
78
79
80
81
268
82
268
83
268
84
258
89
268
90
268
91
268
92
268
93
268
94
276
95
268
96
248
100
248
101
248
102
248
103
248
104
248
105
248
106
248
107
248
108
248
109
234
110
234
111
244
112
244
113
335
114
335
115
70
116
441
117
441
118
441
119
441
120
441
121
441
122
441
123
441
124
217
125
Instruction Code
Control Mode-based Correspondence Table
Advanced
Vector control
magnetic
flux
vector
control
47
C7
0
48
C8
0
×
49
C9
0
×
4A
CA
0
4B
CB
0
4C
CC
0
4D
CD
0
*6
*6
4E
CE
0
4F
CF
0
*6
*6
50
D0
0
×
×
51
D1
0
×
52
D2
0
53
D3
0
×
54
D4
0
×
×
×
×
×
59
D9
0
×
5A
DA
0
×
5B
DB
0
×
5C
DC
0
5D
DD
0
×
5E
DE
0
×
5F
DF
0
×
60
E0
0
×
00
80
1
×
×
×
×
01
81
1
×
×
×
×
02
82
1
×
×
×
×
03
83
1
×
×
×
×
×
×
×
×
04
84
1
×
×
×
×
05
85
1
×
×
×
×
06
86
1
×
×
×
×
07
87
1
×
×
×
×
08
88
1
×
×
×
×
09
89
1
0A
8A
1
0B
8B
1
×
×
×
×
0C
8C
1
×
×
×
×
0D
8D
1
×
×
×
0E
8E
1
×
×
×
0F
8F
1
10
90
1
11
91
1
12
92
1
13
93
1
14
94
1
15
95
1
16
96
1
17
97
1
18
98
1
19
99
1
×
124
PARAMETER
Real sensorless
vector control
Speed
Torque
control
control
×
×
×
×
×
×
×
2
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
*8
×

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e700Fr-d700Fr-f700

Table of Contents