DID Call by Time Schedule
DID Call by Time Schedule allows for 100 programmed DID Conversion table entries (PRG 22-17-01)
that can be routed based on Time Patterns. Each DID Conversion table has a maximum of eight
programmable Time Patterns and each Time Pattern can reference any of the 2000 different Dial-In
Conversion table entries in PRG 22-11-01.
00:00
Time Pattern
PRG 22-17
PRG 22-11-01
100 incoming
PRG 22-11-02
Table No.
1~100
Direct Inward Dialing (DID)
Example 1 (Automatic Change)
09:00
12:00
1
2
2
1
101 incoming
PRG 22-11-01 and PRG 22-11-02
Table No.
1
2
3
Receive Dial
Time Pattern
1111
13:00
3
3
102 incoming
101 incoming
Receive Dial
No setting
No setting
No setting
PRG 22-17
Start Time
1
00:00
2
09:00
3
12:00
4
13:00
5
18:00
6
00:00
7
00:00
8
00:00
Document Revision 4C
18:00
4
5
2
1
100 incoming
Transfer Dial
100
101
102
End Time
09:00
12:00
13:00
18:00
00:00
00:00
00:00
00:00
00:00
PRG 22-11
1
2
3
2
1
0
0
0