Outgoing calls on SIP are not possible under the following conditions:
SIP configuration failed
SIP registration failed
CPUII and MG16 link down
Lack of MG16 DSP resource
Lack of MG16 bandwidth
IPK II SIP does not support T.38 FAX.
SIP IP Trunks use the PVA(X)-U( ) ETU Media Gateway (MG16 application). The media
gateway card controls and interprets RTP messaging from the SIP IP Trunks to the Elite
IPK II Processor, therefore KSU Programming (PRG 84-05-03) Master/Slave
determination is NOT required.
The MG16 Application consumes 16 logical trunk ports, only when using an SIP trunk.
SIP Trunk does not support multi-SIP Server registration.
SIP Station and SIP Trunk required license key for activation. Once activated, the SIP
Client license may be shared between SIP Station and SIP Trunks.
The maximum number of the SIP Trunks is 200.
SIP protocol (RFC3261) is used.
When using SIP Trunks as Interconnect, and using it to grab a trunk out of the remote
system, the trunk access code must be an F-Route and not a Trunk.
Version 1600 does not support the options for configuring 20 or 24 ports in Program
10-40-02: VoIP Trunk Availability.
Version 1600 does not support Program 10-03-01: MG-CCIS PKS – Logical Port Number
of CCIS over IP.
PVA Combo Card Service Conditions
Version 2000 or higher is required to support the PVA Combo Card Application.
The PVA Combo Card Application can support 24 DSP resources which may be configured
to support the MG16 or the CCISoIP application.
The PVA Combo Card CCISoIP Trunks and SIP Trunks Logical Port Numbers are
determined by the following:
SIP Trunks
2 - 580
PVA(X)-U( ) ETU License Registration
SIP Client License Registration
Elite IPK II Program 10-41-01 SIP Trunk Availability
Electra Elite IPK II
IP Trunk (SIP) – MG16