14.2 System Monitor

The system monitor function is capable of monitoring and changing the devices within a target controller.
It is intended to troubleshoot the controller system and to streamline maintenance operations.
By installing the system monitor, an extended function OS, from drawing software into the GOT, you can
monitor and test the devices of the controller and the buffer memory of the intelligent function module.
Any device on four dedicated screens can be monitored
1
The system monitor function comprises four monitors - entry monitor, batch monitor, TC monitor, and
BM monitor, and you can monitor any device according to the application.
The entry monitor function monitors up to 8 controller devices
entered by the user in a single window.
(
Subsection 14.2.10 Entry monitor)
The TC monitor function monitors the present value, set
value, contact point, and coil of up to 8 controller timers (T)/
counters (C) from the device number specified by the user in
a single window.
(
Subsection 14.2.17 TC Monitor (Monitoring Timers
and Counters))
14 - 2
14.2 System Monitor
14.1.2 Display operation of debug
Entry monitor
TC monitor
Batch monitor
The batch monitor function monitors up to 16 controller
devices from the device number specified by the user in a
single window.
(
Subsection 14.2.14 Batch monitor)
BM monitor (monitoring Buffer memory)
The BM monitor function monitors up to 16 devices from the
initial device number in the buffer memory of the intelligent
function module specified by the user in a single window.
(
Subsection 14.2.21 BM monitor (monitoring buffer
memory))