14.2.28 Test operation procedure
Test operation takes place by setting on the setting key window screen the name and number of a device,
initial device number of the buffer memory, and the initial I/O of the module or entering change values.
This subsection takes a change of set values as an example to describe the test operation procedure.
Touch the
1
SET VAL
The setting key window screen appears.
Using the
and
2
The keyboard displayed depends on the position of the cursor, as shown below.
The position of the cursor displayed
Keyboard displayed when the cursor is
placed in the device name box
Keyboard displayed when the cursor is
placed in the device number box
If necessary, enter numbers or characters on the keyboard.
3
•
key: Use the
Del
•
AC
key: Use the
• The
and the keys on which nothing is displayed are not available.
• For further information about the setting ranges, see the following:
Subsection 14.2.27 Information and set items displayed on each setting key window screen
Entry is completed by touching the
4
The keyboard closes by touching the
5
key on the test menu screen.
keys, move the cursor to the item you want to set.
key to delete an entered character.
Del
AC
key to delete all characters under the cursor.
key.
Enter
key.
14.2 System Monitor
14.2.28 Test operation procedure
9
10
11
12
13
14
15
16
14 - 45