18.2 List of Error Message/System Alarm

The system alarm detected with GOT is shown below.
Error
Error message
code
Set monitor points too large.
303
Decrease setting points.
Set trigger points too large.
304
Decrease setting points.
No project data.
306
Download screen data.
307 Monitor device not set
No comment data.
308
Download comment.
Device reading error.
309
Correct device.
Project data does not exist or out
310
of range.
No. of alarm has exceeded upper
311
limit.
Delete restored alarm.
No. of sampling has exceeded
312
upper limit.
Delete collected data.
Device writing error.
315
Correct device.
Cannot display or input operation
316
value.
Review expression.
Specified object does not exist or
320
out of range.
Station No. for monitor device is
321
wrong
The number of objects of the screen to be displayed is too large and the
system work area cannot be secured.
Decrease the number of objects from the displayed screen. For the
number of maximum objects for 1 screen, refer to the following.
GT Designer2 Version
GT Designer3 Version1 Screen Design Manual (Fundamentals)
When cycle is / ON and when cycle is / OFF the number of objects used
exceeds 100.
Decrease the number of objects.
The project data is not downloaded to the built-in flash memory.
Download the project data to the built-in flash memory.
The monitor device of the object is not set.
Set the monitor device of the object.
The comment file does not exist.
Create the comment file and download to GOT.
The error occurred when reading a continuous device.
Correct the device.
1. Specified base screen / window screen does not exist in the project
data.
2. Specified base screen / window screen is out of the permissible area.
Specify the existing base screen / window screen.
The number of alarm histories that can be observed by the alarm history
display function has exceeded the maximum points (1024 points).
Delete the restored history to decrease the number of alarm histories.
The collection frequency exceeded the upper limit when "Store Memory"
and "Accumulate/Average" were set in the scatter graph.
1. Approve "Clear trigger" setup in the scatter graph.
2. Set the "Operation at frequency over time" and "initialize and continue"
in scatter graph.
Error occurred while writing in the device.
Correct the device.
In indirect specification of comment/parts number, the data operation
result exceeded the range in which device type can be expressed.
Review the data operational expression, in order not exceeding the range
in which the device type can be expressed.
The part file does not exist.
Create the part file and download to GOT.
Check the monitor target station No. of the project data.
18.2 List of Error Message/System Alarm