Mitsubishi Electric GT11 User Manual page 292

Graphic operation terminal
Hide thumbs Also See for GT11:
Table of Contents

Advertisement

Displays and key functions
2
The following describes the displays for the list monitor.
1)
No.
1)
List display area
2)
Keys
3)
*1
The status of contacts and coils is displayed as below.
LD, AND, OR(Contact instruction (Normal open))
LDI, ANI, ORI(Contact instruction (Normal close))
OUT, SET
RST
MC, STL
LDP, ANDP, ORP, LDF, ANDF, ORF
(Rise or fall contact instruction)
14 - 110
14.4 MELSEC-FX List Editor
14.4.16 List monitor
Item
*1
The status of contacts and coils is displayed on the left of device displays.
The same operations as in the READ mode of the FX list editor can be executed.
Subsection 14.4.7 Sequence program display
Ends the list monitor.
When the list monitor is executed on the FX list editor screen, the screen is switched to
the FX list editor screen.
Type of instruction
Display contents
Description
Contact
Contact
TC: Coil
Except TC: Contact
TC: Reset
Word device
Except TC and word
device: Contac
Contact
Not monitored
3)
2)
Status
Not displayed
Displayed
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
OFF
Value: 0
Value: Except 0
OFF
ON
ON
OFF
Always
not displayed