14.2 System Monitor
14.2.7 Switching the display format (DEC/HEX) and comment/no-comment display
(1) Changing the comment or comment capacity of the controller
If you change a comment or comment capacity of the controller after the system
monitor function is activated, the comment may not be properly displayed on each
monitor screen.
After a comment or comment capacity is changed, turn off the GOT and turn it on
again.
(2) Switching the display format (DEC/HEX)
The present value of word devices and the present value and set value of timers/
counters will be displayed in decimal or hexadecimal numbers.
(3) Switching comment/no-comment display
The comments written to the target controller will be displayed or not be displayed.
(Priority of comment display: Extension comment > Comment)
(4) Comment/No-comment display
(a) The BM monitor does not display comments.
(b) Comments will not be displayed when any of the CPUs listed below is
monitored.
• FXCPU
• QnACPU or Q series motion controller CPU whose date on the rating plate
is earlier than 9707B
(c) Comments will not be displayed when any of the devices listed below is
monitored.
• Internal device of the GOT (GB, GD, GS)
• Host device (X,Y, WW, WR) when a CC-Link is connected
(d) Displaying the comments of QCPUs (Q02CPU, Q02HCPU, Q06HCPU,
Q12HCPU, Q25HCPU, Q12PHCPU, Q25PHCPU, Q12PRHCPU,
Q25PRHCPU, Q02UCPU, Q03UDCPU, Q04UDHCPU, Q06UDHCPU)
Comments will not be displayed when the following PLC parameters (PLC file
settings) are set:
• When the comment file is set to "Not used"
• When the comment file is set to "Use the same file name as the program"
• When a password is set to the comment file
• When a comment file is stored in program memory
(e) Displaying the comments of QCPUs (Q00JCPU, Q00CPU, Q01CPU)
Comments will not be displayed when the following PLC parameter (PLC file
setting) is set:
• When the comment file "MAIN" does not exist in the program memory
(f) Displaying the comments of QnACPUs
With a QnACPU whose date on the rating plate is earlier than 9707B,
comments cannot be displayed.
Use a QnACPU whose date on the rating plate is 9707B or later.
Also, comments will not be displayed when the following settings are made to
the PLC parameter (PLC file setting) is set.
• When the comment file is not set "Not used"
• When the comment file is set to "Use the same file name as the program"
• When a keyword is entered for each memory